SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-168893"
 

Sökning: id:"swepub:oai:DiVA.org:liu-168893" > Development of a re...

Development of a reliable bioanalytical method based on prostate specific antigen trapping on the cavity of molecular imprinted polymer towards sensing of PSA using binding affinity of PSA-MIP receptor : A novel biosensor

Abbasy, Leila (författare)
Tabriz University of Medical Sciences, Iran
Mohammadzadeh, Arezoo (författare)
Tabriz University of Medical Sciences, Iran
Hasanzadeh, Mohammad (författare)
Tabriz University of Medical Sciences, Iran
visa fler...
Razmi, Nasrin (författare)
Linköpings universitet,Fysik, elektroteknik och matematik,Tekniska fakulteten
visa färre...
 (creator_code:org_t)
Elsevier, 2020
2020
Engelska.
Ingår i: Journal of Pharmaceutical and Biomedical Analysis. - : Elsevier. - 0731-7085 .- 1873-264X. ; 188
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study, electrically-conducting poly [Toluidine Blue (PTB)] was applied as artificial receptor. It was organized by molecular imprinting approaches and via electrochemical technique for the sensitive monitoring of prostate-specific antigen (PSA). The protein-imprinted PTB was electropolymerized in a pre-formed glutaraldehyde-cysteamine (GA-Cys A) matrix on the surface of gold electrode, which significantly boosted the stability against degradation of the Molecular Imprinted Polymer (MIP) on the surface of pre-modified gold electrode. Moreover, the MIP bio-receptor ability towards protein recognition was explored by some electrochemical techniques. The binding affinity of MIP system was considerably upper than that of non-imprinted polymer (NIP) system, indicating the success of the method in generating imprinted materials that was specifically use to PSA protein. The incubation of the MIP modified electrode in various concentration of PSA (from 1-60 μg/L) resulted in the increase of the Fe (CN)63-/4- redox peak current. The bio-device also showed linear response from 1-60 μg/L and LLOQ of 1 μg/L by using DPV technique, leading to PSA monitoring in clinical samples. The proposed MIP-based biosensor was satisfactorily applied to the determination of PSA in human plasma samples. Therefore, the developed bio-device provides a new approach for sensitive, simple, rapid, and cost-effective monitoring of 1 μg/L of PSA. Notably, this approach could appear as an appropriate candidate for point-of-care (POC) use in clinical and biomedical analyses.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Binding affinity
Biomacromolecules
Biomedical analysis
Biosensor
Encapsulation
Prostate cancer.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abbasy, Leila
Mohammadzadeh, A ...
Hasanzadeh, Moha ...
Razmi, Nasrin
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Journal of Pharm ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy