Virtual EEG-electrodes : Convolutional neural networks as a method for upsampling or restoring channels

Svantesson, Mats, 1975- (författare)
Linköpings universitet,Centrum för social och affektiv neurovetenskap,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Neurofysiologiska kliniken US
Olausson, Håkan, 1965- (författare)
Linköpings universitet,Centrum för social och affektiv neurovetenskap,Medicinska fakulteten,Region Östergötland, Neurofysiologiska kliniken US
Eklund, Anders, 1981- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Statistik och maskininlärning,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
visa fler...
Thordstein, Magnus (författare)
Linköpings universitet,Avdelningen för neurobiologi,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Neurofysiologiska kliniken US
visa färre...
 (creator_code:org_t)
Elsevier, 2021
2021
Engelska.
Ingår i: Journal of Neuroscience Methods. - : Elsevier. - 0165-0270 .- 1872-678X.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BackgroundIn clinical practice, EEGs are assessed visually. For practical reasons, recordings often need to be performed with a reduced number of electrodes and artifacts make assessment difficult. To circumvent these obstacles, different interpolation techniques can be utilized. These techniques usually perform better for higher electrode densities and values interpolated at areas far from electrodes can be unreliable. Using a method that learns the statistical distribution of the cortical electrical fields and predicts values may yield better results.New MethodGenerative networks based on convolutional layers were trained to upsample from 4 or 14 channels or to dynamically restore single missing channels to recreate 21-channel EEGs. 5,144 h of data from 1,385 subjects of the Temple University Hospital EEG database were used for training and evaluating the networks.Comparison with Existing MethodThe results were compared to spherical spline interpolation. Several statistical measures were used as well as a visual evaluation by board certified clinical neurophysiologists. Overall, the generative networks performed significantly better. There was no difference between real and network generated data in the number of examples assessed as artificial by experienced EEG interpreters whereas for data generated by interpolation, the number was significantly higher. In addition, network performance improved with increasing number of included subjects, with the greatest effect seen in the range 5–100 subjects.ConclusionsUsing neural networks to restore or upsample EEG signals is a viable alternative to spherical spline interpolation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
NATURVETENSKAP  -- Data- och informationsvetenskap -- Datavetenskap (hsv//swe)
NATURAL SCIENCES  -- Computer and Information Sciences -- Computer Sciences (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Deep learning; Convolutional neural networks; Electroencephalography; Signal reconstruction; Spatial upsampling; Spherical spline interpolation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy