Optical Brain Biopsy with a Fluorescence and Vessel Tracing Probe

Richter, Johan (författare)
Linköpings universitet,Tekniska fakulteten,Avdelningen för medicinsk teknik,Region Östergötland, Neurokirurgiska kliniken US
Haj-Hosseini, Neda (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
Milos, Peter (författare)
Linköpings universitet,Medicinska fakulteten,Avdelningen för neurobiologi,Region Östergötland, Neurokirurgiska kliniken US
visa fler...
Hallbeck, Martin (författare)
Linköpings universitet,Avdelningen för neurobiologi,Medicinska fakulteten,Region Östergötland, Klinisk patologi
Wårdell, Karin (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten,MINT
visa färre...
 (creator_code:org_t)
2021-10
2021
Engelska.
Ingår i: Operative Neurosurgery. - : Oxford University Press. - 2332-4252 .- 2332-4260. ; 21:4, s. 217-224
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND Accurate stereotactic biopsies of brain tumors are imperative for diagnosis and tailoring of the therapy. Repetitive needle insertions enhance risks of brain lesioning, hemorrhage, and complications due to prolonged procedure.OBJECTIVE To investigate clinical benefits of a combined 5-aminolaevulinic acid (5-ALA) fluorescence and laser Doppler flowmetry system for the detection of malignant brain tumor and blood vessels in stereotactic biopsies.METHODS Planning of targets and trajectories was followed by optical measurements in 20 patients, using the Leksell Stereotactic System and a manual insertion device. Fluorescence spectra, microvascular blood flow, and tissue grayness were recorded each millimeter along the paths. Biopsies were taken at preplanned positions. The diagnoses were compared with the fluorescence signals. The recordings were plotted against measurement positions and compared. Sites indicating a risk of hemorrhage were counted as well as the time for the procedures.RESULTS Signals were recorded along 28 trajectories, and 78 biopsies were collected. The final diagnosis showed 17 glioblastomas, 2 lymphomas, and 1 astrocytoma grade III. Fluorescence was seen along 23 of the paths with 4 having the peak of 5-ALA fluorescence 3 mm or more from the precalculated target. There was increased microcirculation in 40 of 905 measured positions. The measurement time for each trajectory was 5 to 10 min.CONCLUSION The probe provided direct feedback of increased blood flow along the trajectory and of malignant tissue in the vicinity of the target. The method can increase the precision and the safety of the biopsy procedure and reduce time.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Biopsy
Optical
Tumor
Fluorescence
Spectroscopy
Stereotactic navigation
5-ALA

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Richter, Johan
Haj-Hosseini, Ne ...
Milos, Peter
Hallbeck, Martin
Wårdell, Karin
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Operative Neuros ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy