Towards a reduction of emissions and cost-savings in homes: Techno-economic and environmental impact of two different solar water heaters

Agyekum, Ephraim Bonah (författare)
Ural Fed Univ, Russia
Ampah, Jeffrey Dankwa (författare)
Tianjin Univ, Peoples R China
Khan, Tahir (författare)
Zhejiang Univ, Peoples R China
visa fler...
Giri, Nimay Chandra (författare)
Centurion Univ Technol & Management, India; Centur Univ Technol & Managemention, India
Hussien, Abdelazim (författare)
Linköpings universitet,Programvara och system,Tekniska fakulteten,Fayoum Univ, Egypt; Appl Sci Private Univ, Jordan; Middle East Univ, Jordan
Velkin, Vladimir Ivanovich (författare)
Ural Fed Univ, Russia
Mehmood, Usman (författare)
Bahcesehir Cyprus Univ, Turkiye; Univ Punjab, Pakistan
Kamel, Salah (författare)
Aswan Univ, Egypt
visa färre...
 (creator_code:org_t)
ELSEVIER, 2024
2024
Engelska.
Ingår i: Energy Reports. - : ELSEVIER. - 2352-4847. ; 11, s. 963-981
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • South Africa currently has the highest carbon emission intensity per kilowatt of electricity generation globally, and its government intends to reduce it. Some of the measures taken by the government include a reduction of emissions in the building sector using solar water heating (SWH) systems. However, there is currently no study in the country that comprehensively assesses the technical, economic, and environmental impact of SWH systems across the country. This study therefore used the System Advisor Model (SAM) to model two different technologies of SWH systems (i.e., flat plate (FPC) and evacuated tube (EPC) SWH) at five different locations (i.e., Pretoria, Upington, Kimberley, Durban, and Cape Town) strategically selected across the country. According to the study, the optimum azimuth for both the evacuated tube and flat plate SWH system in South Africa is 0 degrees. Installing FPC and EPC at the different locations would yield payback periods of 3.2 to 4.4 years and 3.5 to 4.3 years, respectively. Comparably, levelized cost of energy for the FPC and EPC will range from 7.47 to 9.62 cents/kWh and 7.66 to 9.24 cents/kWh, respectively, based on where the SWH system is located. Depending on where the facility is located, the annual cost savings for the FPC system would be between $486 and $625, while the EPC system would save between $529 and $638. Using SWHs can reduce CO2 emissions by 75-77% for the evacuated tube system and 69-76% for the flat plate system annually, depending on the location.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)

Nyckelord

Solar water heating; Domestic hot water; Techno-economic analysis; Evacuated tube; Flat Plate SWH

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy