Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging

Karlsson, M G Daniel, 1974- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
Hübbert, Laila (författare)
Östergötlands Läns Landsting,Hjärtcentrum
Lönn, Urban (författare)
Östergötlands Läns Landsting,Hjärtcentrum
visa fler...
Janerot-Sjöberg, Birgitta, 1958- (författare)
KTH,Östergötlands Läns Landsting,Hjärtcentrum,Medicinsk teknik
Ahn, Henrik Casimir, 1949- (författare)
Östergötlands Läns Landsting,Hjärtcentrum
Wårdell, Karin, 1959- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,MINT
visa färre...
 (creator_code:org_t)
Springer, 2004
2004
Engelska.
Ingår i: Medical and Biological Engineering and Computing. - : Springer. - 0140-0118 .- 1741-0444. ; 42:6, s. 770-776
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Tissue motion of the beating heart generates large movement artifacts in the laser Doppler perfusion monitoring (LDPM) signal. The aim of the study was to use tissue Doppler imaging (TDI) to localise intervals during the cardiac cycle where the influence of movement artifacts on the LDPM signal is minimum. TDI velocities and LDPM signals were investigated on three calves, for normal heartbeat and during occlusion of the left anterior descending coronary artery. Intervals of low tissue velocity (TDIint<1 cm s−1) during the cardiac cycle were identified. During occlusion, these intervals were compared with low LDPM signal intervals (LDPMint<50% compared with baseline). Low-velocity intervals were found in late systole (normal and occlusion) and late diastole (normal). Systolic intervals were longer and less sensitive to heart rate variation compared with diastolic ones. The overlap between LDPMint and TDIint in relation to TDIint length was 84±27% (n=14). The LDPM signal was significantly (p<0.001, n=14) lower during occlusion if calculated during minimum tissue motion inside TDIint), compared with averaging over the entire cardiac cycle without taking tissue motion into consideration. In conclusion, movement artifacts are reduced if the LDPM signal is correlated to the ECG and investigated during minimum wall motion. The optimum interval depends on the application; late systole and late diastole can be used.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy