Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level

Yamaguchi, M. (författare)
Faculty of Engineering Toyama University, Japan
Kawabata, Y. (författare)
Faculty of Engineering Toyama University, Japan
Kambe, S. (författare)
Faculty of Engineering Toyama University, Japan
visa fler...
Wårdell, Karin, 1959- (författare)
Linköpings universitet,Tekniska högskolan,Biomedicinsk instrumentteknik,MINT
Nyström, Fredrik, 1963- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Internmedicin,Endokrin- och magtarmmedicinska kliniken US
Naitoh, K. (författare)
Suzuken Co. Ltd. Nagoya, Japan
Yoshida, H. (författare)
Nipro Co. Shiga, Japan
visa färre...
 (creator_code:org_t)
Springer, 2004
2004
Engelska.
Ingår i: Medical and Biological Engineering and Computing. - : Springer. - 0140-0118 .- 1741-0444. ; 42:3, s. 322-327
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Development of a non-invasive method for measuring the blood glucose level is an urgent necessity, and putting such a method into practical use will enable some of the physical and mental stress that patients with diabetes have to endure to be removed. To realise a non-invasive blood glucose monitor, the gingival crevicular fluid (GCF) was measured. A GCF-collecting device was developed that was designed to be disposable, biocompatible and small enough to be inserted in the gingival crevice for collection of a sub-microlitre sample of GCF. Also, a high-sensitivity glucose testing tape incorporated in the device was developed. Red laser light in a portable optical device measured the colour density of the testing tape. Standard glucose solutions were used to investigate the measurement accuracy of the GCF glucose monitor and showed a correlation coefficient of R=0.99 (n=20) between the optical density and the glucose levels. The GCF glucose monitor was evaluated on healthy Swedish and Japanese adults (n=10) and both GCF glucose levels (GCFLs) and blood glucose levels (BGLs) were measured in conjunction with meal loads. The GCFLs were about 1/10-1/560 lower than the BGLs. No difference in the range of GCFLs between the Swedish and the Japanese subjects was observed. Therefore it was concluded that physique, body mass index and life-style, such as dietary habit, did not significantly influence the GCFLs. Further, the correlation coefficients of all the subjects were 0.70 and 0.88 with each group. It was suggested that GCF could be used as a method of non-invasive blood glucose measurement.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy