SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-24273"
 

Sökning: id:"swepub:oai:DiVA.org:liu-24273" > Evaluation of patie...

Evaluation of patient-absorbed doses during coronary angiography and intervention by femoral and radial artery access

Sandborg, Michael, 1961- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Medicinsk radiofysik,Radiofysikavdelningen
Fransson, Sven Göran, 1949- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Institutionen för medicin och vård,Kardiologiska kliniken
Pettersson, Håkan, 1956- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Medicinsk radiofysik,Radiofysikavdelningen
 (creator_code:org_t)
Springer Science and Business Media LLC, 2004
2004
Engelska.
Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 14:4, s. 653-658
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to compare the radiation dose to patients during coronary angiography (CA) and coronary intervention (percutaneous transluminal coronary angioplasty, PTCA) by the femoral or radial artery access routes. A plane-parallel ionisation chamber, mounted on an under-couch X-ray tube (Siemens Coroskop TOP with an optional dose reduction system), recorded the dose-area product (DAP) to the patient from 40 coronary angiographies and 42 coronary interventions by the femoral route. The corresponding numbers for radial access were 36 and 24, respectively. Using a human-shaped phantom, conversion factors between maximum entrance surface dose and DAP were derived for CA and CA plus PTCA, respectively. The dose to the staff was measured with TL dosimeters for 22 examinations. Fluoroscopy time and DAP were significantly (p=0.003) larger using the radial access route for coronary angiography (7.5 min, 51 Gy cm2) than the corresponding values obtained from femoral access route (4.6 min, 38 Gy cm2. For CA plus PTCA the fluoroscopy time and DAP were larger for radial access (18.4 min, 75 Gy cm2) than for femoral access (12.5 min, 47 Gy cm2, p=0.013). In our experience, radial access did significantly prolong the fluoroscopy time and increase the patient doses.

Nyckelord

cornary angiography
coronary intervention
femoral access
radial access
patient doses
fluoroscopy
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy