Analysis and processing of laser Doppler perfusion monitoring signals recorded from the beating heart
-
- Karlsson, Daniel M G, 1974- (författare)
- Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
-
- Ahn, Henrik Casimir, 1949- (författare)
- Östergötlands Läns Landsting,Hjärtcentrum
-
- Lönn, Urban (författare)
- Östergötlands Läns Landsting,Hjärtcentrum
-
visa fler...
-
- Wårdell, Karin, 1959- (författare)
- Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,MINT
-
visa färre...
-
(creator_code:org_t)
- Springer, 2003
- 2003
- Engelska.
-
Ingår i: Medical and Biological Engineering and Computing. - : Springer. - 0140-0118 .- 1741-0444. ; 41:3, s. 255-262
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Laser Doppler perfusion monitoring (LDPM) can be used for monitoring myocardial perfusion in the non-beating heart. However, the movement of the beating heart generates large artifacts. Therefore the aim of the study was to develop an LDPM system capable of correlating the laser Doppler signals to the cardiac cycle and to process the signals to reduce the movement artifacts. Measurements were performed on three calves, both on the normal beating heart and during occlusion of the left anterior descending coronary artery (LAD). The recorded LDPM signals were digitally processed and correlated to the sampled ECG. Large variations in the output (perfusion) and DC signals during the cardiac cycle were found, with average coefficients of variation of 0.36 and 0.14 (n-14), respectively. However, sections with a relatively low, stable output signal were found in late diastole, where the movement of the heart is at a minimum. Occlusion of the LAD showed the importance of recording the laser Doppler signals at an appropriate point in the cardiac cycle, in this case late systole, to minimise movement artifacts. It is possible to further reduce movement artifacts by increasing the lower cutoff frequency when calculating the output signal.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
Nyckelord
- MEDICINE
- MEDICIN
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas