SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-25061"
 

Sökning: id:"swepub:oai:DiVA.org:liu-25061" > Comparison of surfa...

Comparison of surface plasmon resonance and quartz crystal microbalance in the study of whole blood and plasma coagulation

Vikinge, Trine P. (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
Hansson, Kenny, 1972- (författare)
Linköpings universitet,Klinisk kemi,Hälsouniversitetet
Sandström, Pär (författare)
Linköpings universitet,Institutionen för fysik, kemi och biologi,Tekniska högskolan
visa fler...
Liedberg, Bo (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
Lindahl, Tomas, 1954- (författare)
Linköpings universitet,Klinisk kemi,Hälsouniversitetet
Lundström, Ingemar (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
Tengvall, Pentti (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
Höök, Fredrik (författare)
Department of Applied Physics, Chalmers University of Technology, Göteborg and Department of Cell and Molecular Biology, Lundberg Institute, Göteborg
visa färre...
 (creator_code:org_t)
2000
2000
Engelska.
Ingår i: Biosensors & bioelectronics. - 0956-5663 .- 1873-4235. ; 15:11-12, s. 605-613
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The coagulation of blood plasma and whole blood was studied with a surface plasmon resonance (SPR) based device and a quartz crystal microbalance instrument with energy dissipation detection (QCM-D). The SPR and QCM-D response signals were similar in shape but differing in time scales, reflecting differences in detection mechanisms. The QCM-D response time was longer than SPR, as a physical coupling of the sample to the substrate is required for molecules to be detected by the QCM-method. Change of sample properties within the evanescent field is sufficient for detection with SPR. Both the SPR signals and the QCM-D frequency and dissipation shifts showed dependency on concentrations of coagulation activator and sensitivity to heparin additions. The ratio of dissipation to frequency shifts, commonly considered to reflect viscoelastic properties of the sample, varied with the concentration of activator in blood plasma but not in whole blood. Additions of heparin to the thromboplastin activated whole blood sample, however, made the ratio variation reoccur. Implications of these observations for the understanding of the blood coagulation processes as well as the potential of the two methods in the clinic and in research are discussed.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp