SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-26713"
 

Sökning: id:"swepub:oai:DiVA.org:liu-26713" > Three-dimensional a...

Three-dimensional adaptive filtering in magnetic resonance angiography

Westin, Carl-Fredrik (författare)
Surgical Planning Laboratory, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts
Wigström, Lars, 1967- (författare)
Linköpings universitet,Klinisk fysiologi,Institutionen för medicinsk teknik,Hälsouniversitetet
Loock, Tomas (författare)
Linköpings universitet,Radiofysik,Radiologi,Hälsouniversitetet
visa fler...
Sjöqvist, Lars, 1962- (författare)
Linköpings universitet,Radiofysik,Radiologi,Hälsouniversitetet
Kikinis, Ron (författare)
Surgical Planning Laboratory, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts
Knutsson, Hans, 1950- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
2001-06-26
2001
Engelska.
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 14:1, s. 63-71
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In order to enhance 3D image data from magnetic resonance angiography (MRA), a novel method based on the theory of multidimensional adaptive filtering has been developed. The purpose of the technique is to suppress image noise while enhancing important structures. The method is based on local structure estimation using six 3D orientation selective filters, followed by an adaptive filtering step controlled by the local structure information. The complete filtering procedure requires approximately 3 minutes of computational time on a standard workstation for a 256 × 256 × 64 data set. The method has been evaluated using a mathematical vessel model and in vivo MRA data (both phase contrast and time of flight (TOF)). 3D adaptive filtering results in a better delineation of small blood vessels and efficiently reduces the high-frequency noise. Depending on the data acquisition and the original data type, contrast-to-noise ratio (CNR) improvements of up to 179% (8.9 dB) were observed. 3D adaptive filtering may provide an alternative to prolonging the scan time or using contrast agents in MRA when the CNR is low.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy