Vessel size estimation in peripheral artery interventions : Are angiographic measurements reliable?

Stenström, Hugo, 1949- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Medicinsk radiologi,Avdelningen för radiologi US
Knutsson, Anders, 1962- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Institutionen för medicin och vård,Avdelningen för radiologi US
Smedby, Örjan, 1956- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Medicinsk radiologi,Avdelningen för radiologi US,Centrum för medicinsk bildvetenskap och visualisering, CMIV
 (creator_code:org_t)
2016-08-30
2005
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 46:2, s. 163-169
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To describe and evaluate a new technique for angiographic measurement of arterial diameters and to make a comparison with other common techniques. Material and Methods: The Angiometer has a radiopaque metal body with six cylindrical segments of varying diameter. Arterial diameter is estimated by visually relating the vessel to these segments. The measurements (method A) were compared: to measuring in relation to a ruler on the table-top by means of compasses (B), to an automated measurement technique (quantitative angiography) utilizing calibration to a catheter of known diameter (C), and to a computer-based distance measurement using the ruler on the table-top as reference (D). Twenty-five patients were studied. Each method was used twice by each of two independent observers. A phantom with four drilled holes, filled with contrast agent, was also studied. Results: The coefficient of variation was highest for method C and lowest for method A. Correlations between readings were highest for method A and lowest for method C. Mean diameter values were highest for method A and lowest for methods B and D. In the phantom experiments, sizes were overestimated by between 5% and 9% with method A, and underestimated by between 4% and 27% with the other methods. Conclusion: In terms of reproducibility and accuracy, the proposed method compares favorably with alternative methods.

Nyckelord

angioplasty
diameter
digital
quantitative angiography
visual
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy