A Canonical correlation approach to heart beat detection in textile ECG measurements

Rattfält, Linda, 1979- (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan,Linköping University, Linköping, Sweden
Ahlström, Christer, 1977- (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan,Linköping University, Linköping, Sweden
Berglin, Lena (författare)
The Swedish School of Textiles, University College of Borås, Borås, Sweden
visa fler...
Lindén, Maria (författare)
Mälardalens högskola,Institutionen för datavetenskap och elektronik,Dept. of Computer Science and Electronics, Mälardalen University, Västerås, Sweden
Hult, Peter, 1964- (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan,Linköping University, Linköping, Sweden
Ask, Per, 1950- (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan,Linköping University, Linköping, Sweden
Wiklund, Urban (författare)
Dept. of Biomedical Engineering & Informatics, Umeå University Hospital, Umeå, Sweden
visa färre...
 (creator_code:org_t)
IEEE, 2006
2006
Engelska.
Ingår i: IET 3rd International Conference On Advances in Medical, Signal and Information Processing, 2006. MEDSIP 2006. - : IEEE. - 0863416586 - 9780863416583 ; , s. 1-4
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Research in textile sensors has lead to new ways to measure electrocardiograms (ECG). However, additional disturbances from e.g. muscular noise and high skin-electrode impedances often result in poor signal quality. The paper contains a simple application of canonical correlation analysis (CCA) on multi channel ECG signals recorded with textile electrodes. Using CCA to solve the blind source separation (BSS) problem, we intend to separate the ECG signal from the various noise sources. The method (CCABSS) was compared to simple averaging of the ECG channels and to the independent component analysis method (ICA). A heart beat detector was used to evaluate the signal quality. Results show that the signal was completely lost while simulating various noise in 33%, 17% and 7% of the cases for averaging, ICA and CCA, respectively.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy