SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-36070"
 

Sökning: id:"swepub:oai:DiVA.org:liu-36070" > A simple, cross-lin...

A simple, cross-linked collagen tissue substitute for corneal implantation

Liu, Yuwen (författare)
Gan, Lisha, 1957- (författare)
Linköpings universitet,Hälsouniversitetet,Oftalmologi
Carlsson, David J (författare)
visa fler...
Fagerholm, Per, 1948- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Oftalmologi,Ögonkliniken US
Lagali, Neil (författare)
University of Ottawa
Watsky, Mitchell A (författare)
Munger, Rejean (författare)
Hodge, William G (författare)
Priest, David (författare)
Griffith, May (författare)
University of Ottawa
visa färre...
 (creator_code:org_t)
Association for Research in Vision and Ophthalmology (ARVO), 2006
2006
Engelska.
Ingår i: Investigative Ophthalmology and Visual Science. - : Association for Research in Vision and Ophthalmology (ARVO). - 0146-0404 .- 1552-5783. ; 47:5, s. 1869-1875
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE. To develop a simple corneal substitute from crosslinked collagen. METHODS. Porcine type I collagen (10%, pH 5), was mixed with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The final homogenous solution was molded to corneal dimensions, cured, and then implanted into rabbits and minipigs by lamellar keratoplasty. The implants were followed for up to 6 months after surgery. Clinical examinations of the cornea included detailed slit lamp biomicroscopy, in vivo confocal microscopy, topography and esthesiometry for nerve function. Histopathologic examinations were also performed on rabbit corneas harvested after 6 months. RESULTS. Cross-linked collagen (refractive index, 1.35) had optical clarity superior to human corneas. Implanted into rabbit and porcine corneas, only 1 of 24 of the surgical corneas showed a slight haze at 6 months after surgery. All other implants showed no adverse reactions and remained optically clear. Topography showed a smooth surface and a profile similar to that of the contralateral nonsurgical eye. The implanted matrices promoted regeneration of corneal cells, tear film, and nerves. Touch sensitivity was restored, indicating some restoration of function. The corneas with implants showed no significant loss of thickness and demonstrated stable host- graft integration. CONCLUSIONS. Collagen can be adequately stabilized, using water soluble carbodiimides as protein cross-linking reagents, in the fabrication of corneal matrix substitutes for implantation. The simple cross-linking methodology would allow for easy fabrication of matrices for transplantation in centers where there is a shortage of corneas, or where there is need for temporary patches to repair perforations in emergency situations. Copyright © Association for Research in Vision and Ophthalmology.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy