SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-37154"
 

Sökning: id:"swepub:oai:DiVA.org:liu-37154" > Age and gender do n...

Age and gender do not influence the ability to detect respiration by photoplethysmography

Nilsson, Lena, 1956- (författare)
Linköpings universitet,Anestesiologi med intensivvård,Hälsouniversitetet
Goscinski, Tomas, 1971- (författare)
Linköpings universitet,Anestesiologi med intensivvård,Hälsouniversitetet
Johansson, Anders, 1972- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Hälsouniversitetet
visa fler...
Lindberg, Lars-Göran (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Hälsouniversitetet
Kalman, Sigga, 1952- (författare)
Linköpings universitet,Anestesiologi med intensivvård,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
2006-10-11
2006
Engelska.
Ingår i: Journal of clinical monitoring and computing. - : Springer Science and Business Media LLC. - 1387-1307 .- 1573-2614. ; 20:6, s. 431-436
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective  The non-invasive technique photopl- ethysmography (PPG) can detect changes in blood volume and perfusion in a tissue. Respiration causes variations in the peripheral circulation, making it possible to monitor breaths using an optical sensor attached to the skin. The respiratory-synchronous part of the PPG signal (PPGr) has been used to monitor respiration during anaesthesia, and in postoperative and neonatal care. Studies addressing possible differences in PPGr signal characteristics depending on gender or age are lacking.Methods  We studied three groups of 16 healthy subjects each during normal breathing; young males, old males and young females, and calculated the concordance between PPGr, derived from a reflection mode PPG sensor on the forearm, and a reference CO2 signal. The concordance was quantified by using a squared coherence analysis. Time delay between the two signals was calculated. In this process, we compared three different methods for calculating time delay.Results  Coherence values ≥0.92 were seen for all three groups without any significant differences depending on age or gender (p = 0.67). Comparison between the three different methods for calculating time delay showed a correlation r = 0.93.Conclusions  These results demonstrate clinically important information implying the possibility to register qualitative PPGr signals for respiration monitoring, regardless of age and gender.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy