SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-46443"
 

Sökning: id:"swepub:oai:DiVA.org:liu-46443" > Accuracy and reprod...

Accuracy and reproducibility in phase contrast imaging using SENSE

Thunberg, Per (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Klinisk fysiologi,Hälsouniversitetet,Department of Biomedical Engineering, Örebro University Hospital, Örebro, Sweden; Department of Biomedical Engineering, Linköping University, Linköping, Sweden; 3Department of Medicine and Care, Division of Clinical Physiology, Linköping University, Linköping, Sweden
Karlsson, Matts (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,Department of Biomedical Engineering, Linköping University, Linköping, Sweden
Wigström, Lars (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Klinisk fysiologi,Hälsouniversitetet,2Department of Biomedical Engineering, Linköping University, Linköping, Sweden; 3Department of Medicine and Care, Division of Clinical Physiology, Linköping University, Linköping, Sweden
 (creator_code:org_t)
2003-10-24
2003
Engelska.
Ingår i: Magnetic Resonance in Medicine. - Hoboken, USA : Wiley. - 0740-3194 .- 1522-2594. ; 50:5, s. 1061-1068
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of this study was to evaluate the accuracy and reproducibility of phase contrast imaging using the sensitivity encoding (SENSE) method at different reduction factors. Analytical expressions were derived that state how reproducibility is influenced for velocity and flow measurements. Computer simulations, and in vitro and in vivo studies were performed in order to validate these expressions and to assess how accuracy is affected when different reduction factors are applied. It was shown that reproducibility depends on the reduction and geometry factors. Since the geometry factor varies spatially, so does the reproducibility for phase contrast imaging. In areas with high geometry factors, the standard deviation (SD) may become so large that aliasing occurs. The accuracy of phase contrast imaging is not influenced directly when SENSE is used, but may be indirectly influenced due to high SDs of the measured phase that may subsequently cause aliasing. The current results show that it is possible to achieve accurate flow measurements even at high reduction factors. By taking the geometry factor into account, it may be possible to find areas where phase contrast imaging is accurate even at high reduction factors.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Flow quantification
Parallel MRI
Phase contrast imaging
Reproducibility
SENSE
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Thunberg, Per
Karlsson, Matts
Wigström, Lars
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Linköpings universitet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy