SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-46757"
 

Sökning: id:"swepub:oai:DiVA.org:liu-46757" > Bone formation afte...

Bone formation after 4 weeks around blood-plasma-modified titanium implants with varying surface topographies : An in vivo study

Goransson, A. (författare)
Göransson, A., Department of Biomaterial Science, Institute of Surgical Science, Göteborg University, Göteborg 40530, Sweden, Department of Prosthetic Dentistry/Dental Material Science, Box 412, Göteborg University, Göteborg 40530, Sweden
Jansson, Eva (författare)
Linköpings universitet,Tekniska högskolan,Institutionen för fysik, kemi och biologi
Tengvall, Pentti (författare)
Linköpings universitet,Tekniska högskolan,Tillämpad Fysik
visa fler...
Wennerberg, A. (författare)
Department of Biomaterial Science, Institute of Surgical Science, Göteborg University, Göteborg 40530, Sweden, Department of Prosthetic Dentistry/Dental Material Science, Box 412, Göteborg University, Göteborg 40530, Sweden
visa färre...
Göransson, A, Department of Biomaterial Science, Institute of Surgical Science, Göteborg University, Göteborg 40530, Sweden, Department of Prosthetic Dentistry/Dental Material Science, Box 412, Göteborg University, Göteborg 40530, Sweden Tekniska högskolan (creator_code:org_t)
2003
2003
Engelska.
Ingår i: Biomaterials. - 0142-9612 .- 1878-5905. ; 24:2, s. 197-205
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of the present study was to investigate and compare the stability and bone ingrowth capacity to screw-shaped titanium implants with five different surface treatments. The implants were: (1) standard turned with a thin blood plasma coat (TP), (2) NaOH-etched dito with pore size 0.2-0.3µm (E), (3) NaOH-etched with pore size 0.2-0.3µm and a thin blood plasma coat (EP), (4) electrochemically oxidised with pore size 1-2µm (O), (5) electrochemically oxidised with pore size 1-2µm and a thin blood plasma coat (OP). A total of 66 implants were divided into the above-described five groups and inserted for 4 weeks into tibia and femur of 11 rabbits. The implants were evaluated by resonance frequency (RF) measurements at the time of insertion and removal, and analysed histomorphometrically at removal. The RF measurements showed that the implant stability was lower in soft bone compared to dense and increased with time. No significant differences were observed between the different surface modifications. The histomorphometric analysis revealed no statistically significant differences between the implants regarding bone-to-metal contact (BMC) and bone area inside the threads (BA). The above results indicate that thin blood plasma-coated and non-coated screw-shaped titanium implants with turned, NaOH-etched and electrochemically etched surface profiles integrate similarly to bone at 1 month of implantation. © 2002 Elsevier Science Ltd. All rights reserved.

Nyckelord

Blood-plasma-coated
Pores
Surface characterisation
Surface modification
Titanium implants
Titanium oxide
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Goransson, A.
Jansson, Eva
Tengvall, Pentti
Wennerberg, A.
Artiklar i publikationen
Biomaterials
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy