SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-56300"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-56300" > Bone Density at Imp...

Bone Density at Implant Sites and Its Relationship to Assessment of Bone Quality and Treatment Outcome

Bergkvist, Göran (författare)
Chonbuk National University,Implantatctr, Kneippgatan 4, SE-60236 Norrköping, Sweden
Sahlholm, Sten (författare)
Östergötlands Läns Landsting,Linköpings universitet,Käkkirurgi,Hälsouniversitetet,Käkkliniken,Linköping Univ Hosp, Dept Oral & Maxillofacial Surg, S-58185 Linköping, Sweden
Klintström, Eva (författare)
Östergötlands Läns Landsting,Linköpings universitet,Medicinsk radiologi,Hälsouniversitetet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Röntgenkliniken i Linköping,Linköping Univ Hosp, Dept Radiol, S-58185 Linköping, Sweden
visa fler...
Lindh, Christina (författare)
Malmö högskola,Odontologiska fakulteten (OD),Malmö University
Koh, Kwang-Joon (författare)
Chonbuk Natl Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Jeonju, South Korea
visa färre...
 (creator_code:org_t)
Quintessence Publishing Co, Inc, 2010
2010
Engelska.
Ingår i: INTERNATIONAL JOURNAL OF ORAL and MAXILLOFACIAL IMPLANTS. - : Quintessence Publishing Co, Inc. - 0882-2786 .- 1942-4434. ; 25:2, s. 321-328
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To investigate the relationship between bone mineral density (BMD) before implant placement, implant stability measures at implant placement, and marginal bone loss of immediately loaded implants after 1 year in situ. Materials and Methods: Consecutively recruited patients received Straumann SLActive implants loaded with fixed provisional prostheses within 24 hours. BMD was measured from computed tomographic images before implant placement. Alveolar bone quality was assessed during surgery. Implant stability-both rotational and as measured with resonance frequency analysis- and marginal bone height were assessed at implant placement and after 1 year. The Pearson correlation coefficient was used to calculate correlations, and significance was considered when P andlt; .05. Results: Twenty-one patients received 137 implants (87 in maxillae and 50 in mandibles). BMD was significantly correlated with bone quality classification in both arches (P andlt; .001). Mean BMD was also significantly correlated with stability values (P andlt; .001). Mean marginal bone loss at implant surfaces differed, but not significantly, at the 1-year follow-up, regardless of BMD values (P = .086) and measured stability (rotational stability P = .34, resonance frequency analysis P = .43) at implant placement. Conclusion: Within the limits of this study, it can be concluded that computed tomographic examination can be used as a preoperative method to assess jawbone density before implant placement, since density values correlate with prevailing methods of measuring implant stability. However, in the short time perspective of 1 year, there were no differences in survival rates or changes in marginal bone level between implants placed in bone tissue of different density.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

bone density
computed tomography
dental implants
immediate loading
implant splinting
radiographic bone density
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy