Soft tissue discrimination ex vivo by dual energy computed tomography

Zachrisson, Helene (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Klinisk fysiologi,Hälsouniversitetet
Engström, E (författare)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
Engvall, Jan (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Klinisk fysiologi,Hälsouniversitetet
visa fler...
Wigström, Lars (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Klinisk fysiologi,Hälsouniversitetet
Smedby, Örjan (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet
Persson, Anders, 1953- (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
Elsevier, 2010
2010
Engelska.
Ingår i: European Journal of Radiology. - : Elsevier. - 0720-048X .- 1872-7727. ; 75:2, s. E124-E128
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: Dual Energy Computed Tomography (DECT) may provide additional information about the chemical composition of tissues compared to examination with a single X-ray energy. The aim of this in vitro study was to test whether combining two energies may significantly improve the detection of soft tissue components commonly present in arterial plaques. METHODS: Tissue samples of myocardial and psoas muscle, venous and arterial thrombus as well as fat from different locations were scanned using a SOMATOM Definition Dual Source CT system (Siemens AG, Medical Solutions, Forchheim, Germany) with simultaneous tube voltages of 140 and 80kV. The attenuation (Hounsfield units, HU) at 80 and 140kV was measured in representative regions of interest, and the association between measured HU values and tissue types was tested with logistic regression. RESULTS: The combination of two energy levels (80 and 140kV) significantly improved (p<0.001) the ability to correctly classify venous thrombus vs arterial thrombus, myocardium or psoas; arterial thrombus vs myocardium or psoas; myocardium vs psoas; as well as the differentiation between fat tissue from various locations. Single energy alone was sufficient for distinguishing fat from other tissues. CONCLUSION: DECT offers significantly improved in vitro differentiation between soft tissues occurring in plaques. If this corresponds to better tissue discrimination in vivo needs to be clarified in future studies.

Nyckelord

Dual-source computed tomography; Dual energy CT imaging; Soft tissue characterization; Plaque
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy