SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-65516"
 

Sökning: id:"swepub:oai:DiVA.org:liu-65516" > Regeneration of fun...

Regeneration of functional nerves within full thickness collagen-phosphorylcholine corneal substitute implants in guinea pigs

McLaughlin, CR (författare)
Univ Ottawa, Ottawa Hosp, Inst Eye, Ottawa, ON K1H 8L6 Canada
Carmen, AM (författare)
Univ Miguel Hernandez, CSIC, Inst Neurociencias Alicante, Alacant 03550, Spain
Carmen, C (författare)
Univ Miguel Hernandez, CSIC, Inst Neurociencias Alicante, Alacant 03550, Spain
visa fler...
Liu, WG (författare)
Tianjin Univ, Sch Mat Sci & Engn, Tianjin 300072, Peoples R China
Belmonte, C (författare)
Univ Miguel Hernandez, CSIC, Inst Neurociencias Alicante, Alacant 03550, Spain
Griffith, May (författare)
Univ Ottawa, Ottawa Hosp, Inst Eye, Ottawa, ON K1H 8L6 Canada
Gallar, J (författare)
Univ Miguel Hernandez, CSIC, Inst Neurociencias Alicante, Alacant 03550, Spain
visa färre...
 (creator_code:org_t)
Elsevier BV, 2010
2010
Engelska.
Ingår i: Biomaterials. - : Elsevier BV. - 0142-9612 .- 1878-5905. ; 31:10, s. 2770-2778
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Our objective was to evaluate promotion of tissue and nerve regeneration by extracellular matrix (ECM) Mimics, using corneal implantation as a model system. Porcine type I collagen and 2-methacryloyloxyethyl phosphorylcholine (MPC) were crosslinked using 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) and moulded into appropriate corneal dimensions to serve as substitutes for natural corneal ECK These were implanted as full thickness grafts by penetrating keratoplasty into the corneas Of guinea pigs after removal of the host tissue, and tracked over eight months, by clinical examination, slit-lamp biomicroscopy, and esthesiometry. Histopathology and ex vivo nerve terminal impulse recordings were performed at three months and at eight months. The implants promoted regeneration of corneal cells, nerves and the tear film, while retaining optical clarity. After three months, electrophysiological recordings showed evidence of mechano-nociceptors, and polymodal units inside the implants, while cold-sensitive units were present only on the peripheral host cornea. Following eight months, the incidence of nerve activity and the frequency of spontaneous firing were higher than in control eyes as reported for regenerating fibers. Active cold nerve terminals also innervated the implant area. We show that ECM mimetic materials can promote regeneration of corneal cells and functional nerves. The simplicity in fabrication and demonstrated functionality shows potential for ECM substitutes in future clinical applications. (C) 2009 Elsevier Ltd. All rights reserved.

Nyckelord

ENDOTHELIAL-CELL PRECURSORS; STEM-CELLS; TRIGEMINAL GANGLION; CATS CORNEA; TRANSPLANTATION; STIMULATION; INNERVATION; NEURONS; FIBERS; UNITS
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy