SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-66090"
 

Sökning: id:"swepub:oai:DiVA.org:liu-66090" > A spectroscopic app...

A spectroscopic approach to imaging and quantification of cartilage lesions in human knee joints

Johansson, Anders (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,BioOptico AB, Teknikringen 10, 583 30 Linköping, Sweden
Sundqvist, Tommy (författare)
Linköpings universitet,Hälsouniversitetet,Medicinsk mikrobiologi
Kuiper, J.-H. (författare)
Keele University School of Medicine, Keele, UK,The Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, UK
visa fler...
Öberg, Åke (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
2011-03-01
2011
Engelska.
Ingår i: Physics in Medicine and Biology. - : IOP. - 0031-9155 .- 1361-6560. ; 56:6, s. 1865-1878
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We have previously described a technology based on diffuse reflectance of broadband light for measuring joint articular cartilage thickness, utilizing that optical absorption is different in cartilage and subchondral bone. This study is the first evaluation of the technology in human material. We also investigated the prospects of cartilage lesion imaging, with the specific aim of arthroscopic integration. Cartilage thickness was studied ex vivo in a number of sites (n = 87) on human knee joint condyles, removed from nine patients during total knee replacement surgery. A reflectance spectrum was taken at each site and the cartilage thickness was estimated using the blue, green, red and near-infrared regions of the spectrum, respectively. Estimated values were compared with reference cartilage thickness values (taken after sample slicing) using an exponential model. Two-dimensional Monte Carlo simulations were performed in a theoretical analysis of the experimental results. The reference cartilage thickness of the investigated sites was 1.60 ± 1.30 mm (mean ± SD) in the range 0–4.2 mm. Highest correlation coefficients were seen for the calculations based on the near-infrared region after normalization to the red region (r = 0.86) and for the green region (r = 0.80).

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Medical engineering
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Johansson, Ander ...
Sundqvist, Tommy
Kuiper, J.-H.
Öberg, Åke
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Artiklar i publikationen
Physics in Medic ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy