SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-69977"
 

Sökning: id:"swepub:oai:DiVA.org:liu-69977" > The attitudes to CP...

The attitudes to CPAP treatment inventory: development and initial validation of a new tool for measuring attitudes to CPAP treatment

Broström, Anders (författare)
Jönköping University,Linköpings universitet,Omvårdnad,Hälsouniversitetet,HHJ, Avdelningen för omvårdnad
Ulander, Martin (författare)
Linköpings universitet,Klinisk neurofysiologi,Hälsouniversitetet,Linköping University
Nilsen, Per (författare)
Linköpings universitet,Socialmedicin och folkhälsovetenskap,Hälsouniversitetet,Linköping University
visa fler...
Svanborg, Eva (författare)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk neurofysiologi,Hälsouniversitetet,Neurofysiologiska kliniken US,Linköping University
Franzén Årestedt, Kristofer (författare)
Linnéuniversitetet,Linköpings universitet,Hälsouniversitetet,Omvårdnad,Institutionen för hälso- och vårdvetenskap, HV
visa färre...
 (creator_code:org_t)
2010-08-31
2011
Engelska.
Ingår i: Journal of Sleep Research. - : Blackwell Publishing Ltd. - 0962-1105 .- 1365-2869. ; 20:3, s. 460-471
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ontinuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS), but low adherence rates are common. The aim was to develop the attitudes to CPAP treatment inventory (ACTI), and to investigate the validity and reliability of the instrument among patients with OSAS. ACTI was developed on the basis of: (i) in-depth interviews with 23 patients; (ii) examination of the scientific literature; and (iii) consensus agreement of a multi-professional expert panel. This yielded five different types of attitudes to CPAP treatment. A prospective longitudinal design was used. Two-hundred and eighty-nine patients with OSAS were recruited at three different CPAP centres. Data were collected with ACTI and obtained from medical records. The homogeneity and internal consistency reliability were satisfactorily reflected by the item-total correlations (0.59-0.81) and Cronbachs alpha (0.89), respectively. Construct validity was confirmed with factor analysis (principal component analysis with orthogonal rotation; PCF). The PCF based on baseline data resulted in a one single-factor solution explaining 69% of the total variance. A confirmatory factor analysis was performed 2 weeks after CPAP initiation, resulting in the same factor solution. No indication of uniform differential item functioning was found. The predictive validity was tested with receiver operating characteristic analyses, and a cut-off of 10 on the ACTI gave a sensitivity of 93% and a specificity of 44% for CPAP termination within 6 months. The satisfactory measurement properties of this new pragmatic instrument are promising and indicate that ACTI can be useful in clinical practice to reliably measure attitudes to CPAP treatment.

Nyckelord

adherence
attitudes
continuous positive airway pressure
obstructive sleep apnoea syndrome
reliability
validity
MEDICINE
MEDICIN
Health and Caring Sciences

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy