SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-71284"
 

Sökning: id:"swepub:oai:DiVA.org:liu-71284" > Anti-sclerostin ant...

Anti-sclerostin antibody and mechanical loading appear to influence metaphyseal bone independently in rats

Agholme, Fredrik (författare)
Linköpings universitet,Ortopedi och idrottsmedicin,Hälsouniversitetet
Isaksson, Hanna (författare)
Department of Applied physics, University of Eastern Finland, Kuopio, Finland
Li, Xiaodong (författare)
Metabolic Disorders, Amgen Inc., Thousand Oaks, CA, USA
visa fler...
Ke, Hua Zhu (författare)
Metabolic Disorders, Amgen Inc., Thousand Oaks, CA, USA
Aspenberg, Per (författare)
Östergötlands Läns Landsting,Linköpings universitet,Ortopedi och idrottsmedicin,Hälsouniversitetet,Ortopedkliniken i Linköping
visa färre...
 (creator_code:org_t)
2011-11-24
2011
Engelska.
Ingår i: Acta Orthopaedica. - : Taylor and Francis. - 1745-3674 .- 1745-3682. ; 82:5, s. 628-632
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and purpose: Sclerostin is produced by osteocytes and is an inhibitor of bone formation. Thus, inhibition of sclerostin by a monoclonal antibody increases bone formation and improves fracture repair. Sclerostin expression is upregulated in unloaded bone and is downregulated by loading. We wanted to determine whether an anti-sclerostin antibody would stimulate metaphyseal healing in unloaded bone in a rat model.Methods: 10-week-old male rats (n = 48) were divided into 4 groups, with 12 in each. In 24 rats, the right hind limb was unloaded by paralyzing the calf and thigh muscles with an injection of botulinum toxin A (Botox). 3 days later, all the animals had a steel screw inserted into the right proximal tibia. Starting 3 days after screw insertion, either anti-sclerostin antibody (Scl-Ab) or saline was given twice weekly. The other 24 rats did not receive Botox injections and they were treated with Scl-Ab or saline to serve as normal-loaded controls. Screw pull-out force was measured 4 weeks after insertion, as an indicator of the regenerative response of bone to trauma.Results: Unloading reduced the pull-out force. Scl-Ab treatment increased the pull-out force, with or without unloading. The response to the antibody was similar in both groups, and no statistically significant relationship was found between unloading and antibody treatment. The cancellous bone at a distance from the screw showed changes in bone volume fraction that followed the same pattern as the pull-out force.Interpretation: Scl-Ab increases bone formation and screwfixation to a similar degree in loaded and unloaded bone.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy