Evaluation of effects of JPEG2000 compression on a computer-aided detection system for prostate cancer on digitized histopathology

Doyle, Scott (författare)
Rutgers University, Piscataway, NJ, USA
Monaco, James (författare)
Rutgers University, Piscataway, NJ, USA
Madabhushi, Anant (författare)
Rutgers University, Piscataway, NJ, USA
visa fler...
Lindholm, Stefan (författare)
Siemens Corporate Research, Princeton, NJ, USA
Ljung, Patric (författare)
Siemens Corporate Research, Princeton, NJ, USA
Ladic, Lance (författare)
Siemens Corporate Research, Princeton, NJ, USA
Tomaszewski, John (författare)
University of Pennsylvania, Philadelphia, PA, USA
Feldman, Michael (författare)
University of Pennsylvania, Philadelphia, PA, USA
visa färre...
 (creator_code:org_t)
2010
2010
Engelska.
Ingår i: From Nano to Macro. - 9781424441266 ; , s. 1313-1316
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • A single digital pathology image can occupy over 10 gigabytes of hard disk space, rendering it difficult to store, analyze, and transmit. Though image compression provides a means of reducing the storage requirement, its effects on CAD (and pathologist) performance are not yet clear. In this work we assess the impact of compression on the ability of a CAD system to detect carcinoma of the prostate (CaP) in histological sections. The CAD algorithm proceeds as follows: Glands in the tissue are segmented using a region-growing algorithm. The size of each gland is then extracted and modeled using a mixture of Gamma distributions. A Markov prior (specifically, a probabilistic pairwise Markov model) is employed to encourage nearby glands to share the same class (i.e. cancerous or non-cancerous). Finally, cancerous glands are aggregated into continuous regions using a distance-hull algorithm. We evaluate CAD performance over 12 images compressed at 14 different compression ratios using JPEG2000. Algorithm performance (measured using the under the receiver operating characteristic curves) remains relatively constant for compression ratios up to 1:256. After this point performance degrades precipitously. We also have an expert pathologist view the compressed images and assign a confidence measure as to their diagnostic fidelity.

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy