SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-78898"
 

Sökning: id:"swepub:oai:DiVA.org:liu-78898" > Estimation of Trabe...

Estimation of Trabecular Thickness in Gray-Scale Images Through Granulometric Analysis

Moreno, Rodrigo (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet
Borga, Magnus (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk informatik,Tekniska högskolan
Smedby, Örjan (författare)
Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping
 (creator_code:org_t)
SPIE, 2012
2012
Engelska.
Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 9780819489630
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • This paper extends to gray-scale the method proposed by Hildebrand and Ru ̈egsegger for estimating thickness of trabecular bone, which is the most used in trabecular bone research, where local thickness at a point is defined as the diameter of the maximum inscribed ball that includes that point. The proposed extension takes advantage of the equivalence between this method and the opening function computed for the granulometry generated by the opening operation of mathematical morphology with ball-shaped structuring elements of different radii. The proposed extension (a) uses gray-scale instead of binary mathematical morphology, (b) uses all values of the pattern spectrum of the granulometry instead of the maximum peak as used for binary images, (c) corrects bias on local thickness estimations generated by partial volume effects, and (d) uses the gray-scale as a weighting function for global thickness estimation. The proposed extension becomes equivalent to the original method when it is applied to binary images. A new non-flat structuring element is also proposed in order to reduce the discretization errors generated by traditional flat structuring elements. Translation invariance can be attained by up-sampling the images through interpolation by a factor of two. Results for synthetic and real images show that the quality of the measurements obtained through the original method strongly depend on the binarization process, whereas the measurements obtained through the proposed extension does not. Consequently, the proposed extension is more appropriate for images with limited resolution where binarization is not trivial. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Thickness estimation
trabecular bone
mathematical morphology
granulometry

Publikations- och innehållstyp

vet (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Moreno, Rodrigo
Borga, Magnus
Smedby, Örjan
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk bildbe ...
Artiklar i publikationen
Progress in Biom ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy