Four-dimensional flow MRI using spiral acquisition

Sigfridsson, Andreas (författare)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Petersson, Sven (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet
Carlhäll, Carljohan (författare)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US,Centrum för medicinsk bildvetenskap och visualisering, CMIV
visa fler...
Ebbers, Tino (författare)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US,Centrum för medicinsk bildvetenskap och visualisering, CMIV
visa färre...
 (creator_code:org_t)
2011-12-08
2012
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley-Blackwell. - 0740-3194 .- 1522-2594. ; 68:4, s. 1065-1073
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to reduce the scan time of four-dimensional flow MRI without sacrificing quality. Three spiral approaches are presented and evaluated in vivo and in vitro against a conventional Cartesian acquisition. In vivo, the performance of each method was assessed in the thoracic aorta in 10 volunteers using pathline-based analysis and cardiac output analysis. Signal-to-noise ratio and background phase errors were investigated in vitro. Using spiral readouts, the scan times of a four-dimensional flow acquisition of the thoracic aorta could be reduced 23-fold, with no statistically significant difference in pathline validity or cardiac output. The shortened scan time improves the applicability of four-dimensional flow MRI, which may allow the technique to become a part of a clinical workflow for cardiovascular functional imaging.

Nyckelord

cine three-dimensional flow
phase contrast
spiral
pathline
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy