SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-87225"
 

Sökning: id:"swepub:oai:DiVA.org:liu-87225" > Polarized Light Spe...

Polarized Light Spectroscopy for Measurement of the Microvascular Response to Local Heating at Multiple Skin Sites

Tesselaar, Erik (författare)
Linköpings universitet,Brännskadevård,Hälsouniversitetet
Bergkvist, Max (författare)
Östergötlands Läns Landsting,Hand- och plastikkirurgiska kliniken US
Sjöberg, Folke (författare)
Östergötlands Läns Landsting,Linköpings universitet,Brännskadevård,Hälsouniversitetet,Hand- och plastikkirurgiska kliniken US,Anestesi- och operationkliniken US
visa fler...
Farnebo, Simon (författare)
Östergötlands Läns Landsting,Linköpings universitet,Kirurgi,Hälsouniversitetet,Hand- och plastikkirurgiska kliniken US
visa färre...
 (creator_code:org_t)
2012-11-20
2012
Engelska.
Ingår i: Microcirculation. - : Informa Healthcare / John Wiley and Sons. - 1073-9688 .- 1549-8719. ; 19:8, s. 705-713
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: To evaluate whether TiVi, a technique based on polarized light, could measure the change in RBC concentration during local heating in healthy volunteers. Methods: Using a custom-made transparent heater, forearm skin was heated to 42 degrees C for 40 minutes while the change in RBC concentration was measured with TiVi. The perfusion response during local heating was measured at the same time with Laser Doppler flowmetry. Results: Mean RBC concentration increased (91 +/- 34 vs. 51 +/- 34 A.U. at baseline, p less than 0.001). The spatial heterogeneity of the RBC concentration in the measured skin areas was 26 +/- 6.4% at baseline, and 23 +/- 4.6% after 40 minutes of heating. The mean RBC concentrations in two skin sites were highly correlated (0.98 at baseline and 0.96 after 40 minutes of heating). The change in RBC concentration was less than the change in perfusion, measured with LDF. Unlike with LDF, a neurally mediated peak was not observed with TiVi in most of the test subjects. Conclusions: TiVi is a valuable technique for measuring the microvascular response to local heating in the skin, and offers a high reproducibility for simultaneous measurements at different skin sites, provided carefully controlled experiments are ensured.

Nyckelord

tissue viability imaging; polarization light spectroscopy; local heating; red blood cell concentration; reproducibility
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy