SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-89619"
 

Sökning: id:"swepub:oai:DiVA.org:liu-89619" > Fully automatic mea...

Fully automatic measurements of axial vertebral rotation for assessment of spinal deformity in idiopathic scoliosis

Forsberg, Daniel (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk informatik,Tekniska högskolan
Lundström, Claes (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medie- och Informationsteknik,Tekniska högskolan
Andersson, Mats (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk informatik,Tekniska högskolan
visa fler...
Vavruch, Ludvig (författare)
Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Neurokirurgi,Hälsouniversitetet,Ortopedkliniken i Linköping
Tropp, Hans (författare)
Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Ortopedi,Hälsouniversitetet,Ortopedkliniken i Linköping
Knutsson, Hans (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk informatik,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
2013-02-26
2013
Engelska.
Ingår i: Physics in Medicine and Biology. - : Institute of Physics (IOP). - 0031-9155 .- 1361-6560. ; 58:6, s. 1775-1787
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Reliable measurements of spinal deformities in idiopathic scoliosis are vital, since they are used for assessing the degree of scoliosis, deciding upon treatment and monitoring the progression of the disease. However, commonly used two dimensional methods (e.g. the Cobb angle) do not fully capture the three dimensional deformity at hand in scoliosis, of which axial vertebral rotation (AVR) is considered to be of great importance. There are manual methods for measuring the AVR, but they are often time-consuming and related with a high intra- and inter-observer variability. In this paper, we present a fully automatic method for estimating the AVR in images from computed tomography. The proposed method is evaluated on four scoliotic patients with 17 vertebrae each and compared with manual measurements performed by three observers using the standard method by Aaro-Dahlborn. The comparison shows that the difference in measured AVR between automatic and manual measurements are on the same level as the inter-observer difference. This is further supported by a high intraclass correlation coefficient (0.971-0.979), obtained when comparing the automatic measurements with the manual measurements of each observer. Hence, the provided results and the computational performance, only requiring approximately 10 to 15 s for processing an entire volume, demonstrate the potential clinical value of the proposed method.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy