SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-89734"
 

Sökning: id:"swepub:oai:DiVA.org:liu-89734" > The potential of du...

The potential of dual-energy computed tomography for quantitative decomposition of soft tissues to water, protein and lipid in brachytherapy

Malusek, Alexandr (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Karlsson, Mattias (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet
Magnusson, Maria (författare)
Linköpings universitet,Datorseende,Tekniska högskolan
visa fler...
Alm Carlsson, Gudrun (författare)
Östergötlands Läns Landsting,Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen US
visa färre...
 (creator_code:org_t)
2013-01-16
2013
Engelska.
Ingår i: Physics in Medicine and Biology. - : Institute of Physics. - 0031-9155 .- 1361-6560. ; 58:4, s. 771-785
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Dosimetric accuracy of radiation treatment planning in brachytherapy depends on knowledge of tissue composition. It has been speculated that soft tissues can be decomposed to water, lipid and protein. The aim of our work is to evaluate the accuracy of such tissue decomposition. Selected abdominal soft tissues, whose average elemental compositions were taken from literature, were decomposed using dual energy computed tomography to water, lipid and protein via the three-material decomposition method. The quality of the decomposition was assessed using relative differences between (i) mass energy absorption and (ii) mass energy attenuation coefficients of the analyzed and approximated tissues. It was found that the relative differences were less than 2% for photon energies larger than 10 keV. The differences were notably smaller than the ones for water as the transport and dose scoring medium. The choice of the water, protein and lipid triplet resulted in negative elemental mass fractions for some analyzed tissues. As negative elemental mass fractions cannot be used in general purpose particle transport computer codes using the Monte Carlo method, other triplets should be used for the decomposition. These triplets may further improve the accuracy of the approximation as the differences were mainly caused by the lack of high-Z materials in the water, protein and lipid triplet.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy