SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-91233"
 

Sökning: id:"swepub:oai:DiVA.org:liu-91233" > Model-based registr...

Model-based registration for assessment of spinal deformities in idiopathic scoliosis

Forsberg, Daniel (författare)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Lundström, Claes (författare)
Linköpings universitet,Medie- och Informationsteknik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Andersson, Mats (författare)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
visa fler...
Knutsson, Hans (författare)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
visa färre...
 (creator_code:org_t)
2013-12-19
2014
Engelska.
Ingår i: Physics in Medicine and Biology. - : Institute of Physics and Engineering in Medicine. - 0031-9155 .- 1361-6560. ; 59:2, s. 311-326
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Detailed analysis of spinal deformity is important within orthopaedic healthcare, in particular for assessment of idiopathic scoliosis. This paper addresses this challenge by proposing an image analysis method, capable of providing a full three-dimensional spine characterization. The proposed method is based on the registration of a highly detailed spine model to image data from computed tomography. The registration process provides an accurate segmentation of each individual vertebra and the ability to derive various measures describing the spinal deformity. The derived measures are estimated from landmarks attached to the spine model and transferred to the patient data according to the registration result. Evaluation of the method provides an average point-to-surface error of 0.9 mm ± 0.9 (comparing segmentations), and an average target registration error of 2.3 mm ± 1.7 (comparing landmarks). Comparing automatic and manual measurements of axial vertebral rotation provides a mean absolute difference of 2.5° ± 1.8, which is on a par with other computerized methods for assessing axial vertebral rotation. A significant advantage of our method, compared to other computerized methods for rotational measurements, is that it does not rely on vertebral symmetry for computing the rotational measures. The proposed method is fully automatic and computationally efficient, only requiring three to four minutes to process an entire image volume covering vertebrae L5 to T1. Given the use of landmarks, the method can be readily adapted to estimate other measures describing a spinal deformity by changing the set of employed landmarks. In addition, the method has the potential to be utilized for accurate segmentations of the vertebrae in routine computed tomography examinations, given the relatively low point-to-surface error.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Forsberg, Daniel
Lundström, Claes
Andersson, Mats
Knutsson, Hans
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk bildbe ...
Artiklar i publikationen
Physics in Medic ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy