SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-92114"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-92114" > Novel biosensors fo...

Novel biosensors for quantitative phytic acid and phytase measurement

Mak, Wing Cheung (författare)
Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
Ng, Yuk Mui (författare)
Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
Chan, Chiyui (författare)
Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
visa fler...
Kwong, Wai Kuen (författare)
Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
Renneberg, Reinhard (författare)
Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
visa färre...
 (creator_code:org_t)
Elsevier, 2004
2004
Engelska.
Ingår i: Biosensors & bioelectronics. - : Elsevier. - 0956-5663 .- 1873-4235. ; 19:9, s. 1029-1035
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Phytase (EC 3.1.3.26) and phytic acid (myo-inositol hexaphosphate) play an important environmental role in poultry industry and have a health aspect in food industry. Novel biosensors have been developed for simple, one step quantitative phytic acid and phytase detection. A system based on the sequentially acting enzyme phytase and pyruvate oxidase (POD) was employed for the development of phytase and phytic acid biosensors. Poly(carbamoylsulphonate) (PCS) hydrogel immobilized POD electrode was applied for the detection of phytase. It was based on the indication of phosphate ions produced by the hydrolysis of phytic acid. The phytase biosensor showed a linear response ranging from 0.5 to 6.0 units/ml. A bi-enzyme sensor based on co-immobilization of phytase and POD was developed for the detection of phytic acid on the basis of amperometric detection of the enzymatically-generated hydrogen peroxide at 0.6 V versus Ag/AgCl. It showed a linear response ranging from 0.2 to 2.0 mM with a detection limit of 0.002 mM.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Phytic acid (myo-inositol hexaphosphate); Phytase; Pyruvate oxidase (POD); Biosensors; Inorganic phosphate

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy