SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-96976"
 

Sökning: id:"swepub:oai:DiVA.org:liu-96976" > Long-term left vent...

Long-term left ventricular support in patients with a mechanical aortic valve

Casimir Ahn, Henrik (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Thorax-kärlkliniken i Östergötland
Granfeldt, Hans (författare)
Östergötlands Läns Landsting,Linköpings universitet,Thoraxkirurgi,Hälsouniversitetet,Thorax-kärlkliniken i Östergötland
Hübbert, Laila (författare)
Östergötlands Läns Landsting,Linköpings universitet,Kardiologi,Hälsouniversitetet,Kardiologiska kliniken US
visa fler...
Peterzén, Bengt (författare)
Östergötlands Läns Landsting,Linköpings universitet,Institutionen för medicin och hälsa,Hälsouniversitetet,Thorax-kärlkliniken i Östergötland
visa färre...
 (creator_code:org_t)
2013-05-22
2013
Engelska.
Ingår i: Scandinavian Cardiovascular Journal. - : INFORMA HEALTHCARE, TELEPHONE HOUSE, 69-77 PAUL STREET, LONDON EC2A 4LQ, ENGLAND. - 1401-7431 .- 1651-2006. ; 47:4, s. 236-239
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives. The presence of a mechanical prosthesis has been regarded as an increased risk of thromboembolic complications and as a relative contraindication for a left ventricular assist device (LVAD). Five patients in our center had a mechanical aortic valve at the time of device implantation and were studied regarding thromboembolic complications. Design. Five patients operated upon with an LVAD (1 HeartMate I (TM), 4 HeartMate II (TM)) between 2002 and 2011 had a mechanical aortic valve at the time of implantation. The first patient had a patch closure of the aortic valve. In four patients, the prosthesis was left in place. Anticoagulants included aspirin, warfarin, and clopidogrel. Results. The average and accumulated treatment times were 150 and 752 days, respectively. Three of the five patients showed early signs of valve thrombosis on echo with concomitant valve dysfunction. Four patients were transplanted without thromboembolic events during pump treatment. One patient died from a hemorrhagic stroke after 90 days on the LVAD. Conclusions. The strategy of leaving a mechanical heart valve in place at the time of LVAD implantation in five patients led to valvular thrombosis in three but did not provoke embolic events. It increased the complexity of postoperative anticoagulation.

Nyckelord

aortic valve
left ventricular support
mechanical valve
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy