SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-99971"
 

Sökning: id:"swepub:oai:DiVA.org:liu-99971" > Live 3D echo guidan...

Live 3D echo guidance of catheter-based endomyocardial injection

Baklanov, Dmitri V. (författare)
Dartmouth Hitchcock Medical Centre, NH, USA
de Muinck, Ebo D. (författare)
Dartmouth Hitchcock Medical Centre, NH, USA
Simons, Michael (författare)
Dartmouth Hitchcock Medical Centre, NH, USA
visa fler...
Moodie, Karen L. (författare)
Dartmouth Hitchcock Medical Centre, NH, USA
Arbuckle, Brenda E. (författare)
Dartmouth Hitchcock Medical Centre, NH, USA
Thompson, Craig A. (författare)
Dartmouth Hitchcock Medical Centre, NH, USA
Palac, Robert T. (författare)
Dartmouth Hitchcock Medical Centre, NH, USA
visa färre...
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Catheterization and cardiovascular interventions. - : Wiley-Blackwell. - 1522-1946 .- 1522-726X. ; 65:3, s. 340-345
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Local delivery of therapeutic agents into the myocardium is limited by suboptimal imaging. We evaluated the feasibility and accuracy of live 313 echo to guide left ventricular endomyocardial injection. An intramyocardial injection catheter was positioned in the left ventricle in five healthy Yorkshire pigs using fluoroscopy. All other catheter manipulations were performed with live biplane and 3D echo guidance. In each animal, a total of 12 endomyocardial injections (volume, 50-100 mu l) of echo contrast mixed with blue tissue dye were performed. Four injections, 10 mm apart, were directed to three myocardial target zones: the anterior septum at the mitral valve level (zone 1); the posterolateral wall between the heads of the papillary muscles (zone 2); and the apex (zone 3). The injections were aimed to form a transverse line in zones 1 and 2 and an inverted triangular pyramid in zone 3. The animals were sacrificed, the hearts were inspected and the left ventricular endocardium was examined to create a map of injection marks. Success, defined as a visible injection of tissue dye, was 95%, and accuracy, defined as an injection into the target zone, was 83%. There was no significant difference in accuracy between the zones. Live 3D echo can successfully guide endomyocardial injections by accurately targeting specific myocardial zones, verifying catheter apposition and, when combined with echo contrast, providing real-time visualization of injectate deposition. (c) 2005 Wiley-Liss, Inc.

Nyckelord

3D echocardiography; catheterization; myocardium
MEDICINE
MEDICIN
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy