SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:lnu-111120"
 

Sökning: id:"swepub:oai:DiVA.org:lnu-111120" > Simultaneous Measur...

Simultaneous Measurement of 11 Antibiotics for Use in the Intensive Care Unit by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry

Woksepp, Hanna (författare)
Linnéuniversitetet,Institutionen för medicin och optometri (MEO),Kalmar County Hospital, Sweden
Karlsson, Louise (författare)
Linköping University, Sweden
Arlemalm, Andreas (författare)
Linköping University, Sweden
visa fler...
Hallgren, Anita (författare)
Linköping University, Sweden
Schön, Thomas (författare)
Linköping University Hospital, Sweden;Linköping University, Sweden;Kalmar County Hospital, Sweden
Carlsson, Björn (författare)
Linköping University, Sweden
visa färre...
 (creator_code:org_t)
Lippincott Williams & Wilkins, 2022
2022
Engelska.
Ingår i: Therapeutic Drug Monitoring. - : Lippincott Williams & Wilkins. - 0163-4356 .- 1536-3694. ; 44:2, s. 308-318
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Recent studies indicate that a high proportion of patients in the intensive care unit fail to attain adequate antibiotic levels. Thus, there is a need to monitor the antibiotic concentration to ensure effective treatment. In this article, the authors aimed to develop an ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous quantification of antimicrobials to assess individualized therapeutic drug monitoring. Methods: A UHPLC-MS/MS method with 11 antibiotics (ciprofloxacin, moxifloxacin, benzylpenicillin, levofloxacin, linezolid, rifampicin, meropenem, cloxacillin, cefotaxime, clindamycin, and piperacillin) was developed. Chromatographic separation was performed using a Kinetex Biphenyl reversed-phase column, with gradient elution using 0.1% formic acid and methanol with 0.1% formic acid. Sample preparation was performed using methanol protein precipitation. The total run time was 5 minutes. Results: For all analytes, the interassay inaccuracies for calibrators were <= 5%. The interday inaccuracies for the quality controls (QCs) were <= 5% for all analytes. The interassay precision for calibration standards ranged between 1.42% and 6.11%. The interassay imprecision for QCs of all antibiotics and concentrations ranged between 3.60% and 16.1%. Interassay inaccuracy and imprecision for the QCs and calibration standards were <= 15% for all drugs, except benzylpenicillin. Conclusions: A rapid UHPLC-MS/MS method was developed for the simultaneous quantification of 11 different antibiotics. Minimal sample preparation was required to ensure a rapid turnaround time. The method was applied to clinical samples collected from 4 intensive care units.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Farmakologi och toxikologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Pharmacology and Toxicology (hsv//eng)

Nyckelord

UHPLC-MS
MS
antibiotics
therapeutic drug monitoring
critically ill patients
clinical application
Pharmacology
Farmakologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy