SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:lnu-117762"
 

Sökning: id:"swepub:oai:DiVA.org:lnu-117762" > Pitfalls in complem...

Pitfalls in complement analysis : A systematic literature review of assessing complement activation

Brandwijk, Ricardo J. M. G. E. (författare)
Hycult Biotechnol bv, Netherlands
Michels, Marloes A. H. M. (författare)
Radboud Univ Nijmegen Med Ctr, Netherlands
van Rossum, Mara (författare)
Hycult Biotechnol bv, Netherlands
visa fler...
de Nooijer, Aline H. (författare)
Radboud Univ Nijmegen Med Ctr, Netherlands
Nilsson, Per H., 1980- (författare)
Linnéuniversitetet,Institutionen för kemi och biomedicin (KOB),Avancerade material,Univ Oslo, Norway;Oslo University Hospital Rikshospitalet, Norway,Linnaeus Ctr Biomat Chem, BMC;HoRB
de Bruin, Wieke C. C. (författare)
Hycult Biotechnol bv, Netherlands
Toonen, Erik J. M. (författare)
Hycult Biotechnol bv, Netherlands
visa färre...
 (creator_code:org_t)
2022-10-18
2022
Engelska.
Ingår i: Frontiers in Immunology. - : Frontiers Media S.A.. - 1664-3224. ; 13
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: The complement system is an essential component of our innate defense and plays a vital role in the pathogenesis of many diseases. Assessment of complement activation is critical in monitoring both disease progression and response to therapy. Complement analysis requires accurate and standardized sampling and assay procedures, which has proven to be challenging. Objective: We performed a systematic analysis of the current methods used to assess complement components and reviewed whether the identified studies performed their complement measurements according to the recommended practice regarding pre-analytical sample handling and assay technique. Results are supplemented with own data regarding the assessment of key complement biomarkers to illustrate the importance of accurate sampling and measuring of complement components. Methods: A literature search using the Pubmed/MEDLINE database was performed focusing on studies measuring the key complement components C3, C5 and/or their split products and/or the soluble variant of the terminal C5b-9 complement complex (sTCC) in human blood samples that were published between February 2017 and February 2022. The identified studies were reviewed whether they had used the correct sample type and techniques for their analyses. Results: A total of 92 out of 376 studies were selected for full-text analysis. Forty-five studies (49%) were identified as using the correct sample type and techniques for their complement analyses, while 25 studies (27%) did not use the correct sample type or technique. For 22 studies (24%), it was not specified which sample type was used. Conclusion: A substantial part of the reviewed studies did not use the appropriate sample type for assessing complement activation or did not mention which sample type was used. This deviation from the standardized procedure can lead to misinterpretation of complement biomarker levels and hampers proper comparison of complement measurements between studies. Therefore, this study underlines the necessity of general guidelines for accurate and standardized complement analysis

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Immunologi inom det medicinska området (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Immunology in the medical area (hsv//eng)

Nyckelord

complement system
complement diagnostics
systematic review
immunoassays
standardization of measurements
complement activation
Immunologi
Immunology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy