Sökning: id:"swepub:oai:DiVA.org:lnu-80280" >
Co-placement optimi...
Co-placement optimization in sensor-reusable cyber-physical digital microfluidic biochips
-
- Li, Jian-De (författare)
- Natl Chung Hsing Univ, Taiwan
-
- Kuo, Chun-Hao (författare)
- Natl Chiao Tung Univ, Taiwan
-
- Lu, Guan-Ruei (författare)
- Natl Chiao Tung Univ, Taiwan
-
visa fler...
-
- Wang, Sying-Jyan (författare)
- Natl Chung Hsing Univ, Taiwan
-
- Li, Katherine Shu-Min (författare)
- Natl Sun Yat Sen Univ, Taiwan
-
- Ho, Tsung-Yi (författare)
- Natl Tsing Hua Univ, Taiwan
-
- Chen, Hung-Ming (författare)
- Natl Chiao Tung Univ, Taiwan
-
- Hu, Shiyan (författare)
- Linnéuniversitetet,Institutionen för datavetenskap och medieteknik (DM),CPS
-
visa färre...
-
(creator_code:org_t)
- Elsevier, 2019
- 2019
- Engelska.
-
Ingår i: Microelectronics Journal. - : Elsevier. - 0959-8324 .- 0026-2692. ; 83, s. 185-196
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Digital microfluidic biochips (DMFBs) facilitate modern healthcare applications. One of the most important applications is point-of-care (POC) clinical diagnosis which is directly related to human health. However, biochemical experiments are usually error-prone, which makes monitoring intermediate results during bioassay execution be required to ensure the correctness of POC clinical diagnosis. To tackle this problem, cyber-physical digital microfluidic biochips with integrated sensors have been proposed and have attracted attention recently. In order to fully utilize the sensors for detection, the reusability of sensors should be taken into consideration during the module placement stage of cyber-physical DMFBs synthesis flow. Moreover, excessive actuation of electrodes may cause reliability degradation and this issuse should also be taken care of during module placement stage. In order to deal with the aforementioned problems, this paper presents the first co-optimization method for both module and sensor placement. Experimental results show that the proposed method can effectively minimize bioassay completion time while meeting all constraints from sensors and electrodes.
Ämnesord
- NATURVETENSKAP -- Data- och informationsvetenskap (hsv//swe)
- NATURAL SCIENCES -- Computer and Information Sciences (hsv//eng)
Nyckelord
- Digital microfluidic biochips
- Cyber-physical sys-tem
- Sensor
- Placement
- Reliability
- Computer Science
- Datavetenskap
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas