SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:lnu-84759"
 

Sökning: id:"swepub:oai:DiVA.org:lnu-84759" > Scoring reading par...

Scoring reading parameters : An inter-rater reliability study using the MNREAD chart

Baskaran, Karthikeyan, Senior Lecturer, 1983- (författare)
Linnéuniversitetet,Institutionen för medicin och optometri (MEO),REVO
Macedo, António Filipe, Senior Lecturer, 1976- (författare)
Linnéuniversitetet,Institutionen för medicin och optometri (MEO),University of Minho Braga, Portugal
He, Yingchen (författare)
University of Minnesota, USA
visa fler...
Hernandez-Moreno, Laura (författare)
University of Minho Braga, Portugal
Queirós, Tatiana (författare)
Hospital de Braga, Portugal
Mansfield, J. Stephen (författare)
SUNY College at Plattsburgh, USA
Calabrèse, Aurélie (författare)
Aix-Marseille University, France;CNRS, France
visa färre...
 (creator_code:org_t)
2019-06-07
2019
Engelska.
Ingår i: PLOS ONE. - : Public Library of Science. - 1932-6203. ; 14:6, s. 1-14
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose First, to evaluate inter-rater reliability when human raters estimate the reading performance of visually impaired individuals using the MNREAD acuity chart. Second, to evaluate the agreement between computer-based scoring algorithms and compare them with human rating. Methods Reading performance was measured for 101 individuals with low vision, using the Portuguese version of the MNREAD test. Seven raters estimated the maximum reading speed (MRS) and critical print size (CPS) of each individual MNREAD curve. MRS and CPS were also calculated automatically for each curve using two different algorithms: the original standard deviation method (SDev) and a non-linear mixed effects (NLME) modeling. Intra-class correlation coefficients (ICC) were used to estimate absolute agreement between raters and/or algorithms. Results Absolute agreement between raters was ‘excellent’ for MRS (ICC = 0.97; 95%CI [0.96, 0.98]) and ‘moderate’ to ‘good’ for CPS (ICC = 0.77; 95%CI [0.69, 0.83]). For CPS, inter-rater reliability was poorer among less experienced raters (ICC = 0.70; 95%CI [0.57, 0.80]) when compared to experienced ones (ICC = 0.82; 95%CI [0.76, 0.88]). Absolute agreement between the two algorithms was ‘excellent’ for MRS (ICC = 0.96; 95%CI [0.91, 0.98]). For CPS, the best possible agreement was found for CPS defined as the print size sustaining 80% of MRS (ICC = 0.77; 95%CI [0.68, 0.84]). Absolute agreement between raters and automated methods was ‘excellent’ for MRS (ICC = 0.96; 95% CI [0.88, 0.98] for SDev; ICC = 0.97; 95% CI [0.95, 0.98] for NLME). For CPS, absolute agreement between raters and SDev ranged from ‘poor’ to ‘good’ (ICC = 0.66; 95% CI [0.3, 0.80]), while agreement between raters and NLME was ‘good’ (ICC = 0.83; 95% CI [0.76, 0.88]). Conclusion For MRS, inter-rater reliability is excellent, even considering the possibility of noisy and/or incomplete data collected in low-vision individuals. For CPS, inter-rater reliability is lower. This may be problematic, for instance in the context of multisite investigations or follow-up examinations. The NLME method showed better agreement with the raters than the SDev method for both reading parameters. Setting up consensual guidelines to deal with ambiguous curves may help improve reliability. While the exact definition of CPS should be chosen on a case-by-case basis depending on the clinician or researcher’s motivations, evidence suggests that estimating CPS as the smallest print size sustaining about 80% of MRS would increase inter-rater reliability.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

MNREAD acuity chart
visual impairment
algorithms
Optometry
Optometri

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • PLOS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy