SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ltu-103396"
 

Sökning: id:"swepub:oai:DiVA.org:ltu-103396" > Concurrent Validity...

Concurrent Validity of Cervical Movement Tests Using VR Technology—Taking the Lab to the Clinic

Forsberg, Karin (författare)
Luleå tekniska universitet,Hälsa, medicin och rehabilitering
Jirlén, Johan (författare)
Luleå tekniska universitet,Hälsa, medicin och rehabilitering
Jacobson, Inger (författare)
Luleå tekniska universitet,Hälsa, medicin och rehabilitering
visa fler...
Röijezon, Ulrik (författare)
Luleå tekniska universitet,Hälsa, medicin och rehabilitering
visa färre...
 (creator_code:org_t)
MDPI, 2023
2023
Engelska.
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 23:24
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Reduced cervical range of motion (ROM) and movement velocity are often seen in people with neck pain. Objective assessment of movement characteristics is important to identify dysfunction, to inform tailored interventions, and for the evaluation of the treatment effect. The purpose of this study was to investigate the concurrent validity of a newly developed VR technology for the assessment of cervical ROM and movement velocity. VR technology was compared against a gold-standard three-dimensional optical motion capture system. Consequently, 20 people, 13 without and 7 with neck pain, participated in this quantitative cross-sectional study. ROM was assessed according to right/left rotation, flexion, extension, right/left lateral flexion, and four diagonal directions. Velocity was assessed according to fast cervical rotation to the right and left. The correlations between VR and the optical system for cervical ROM and velocity were excellent, with intraclass correlation coefficient (ICC) values > 0.95. The mean biases between VR and the optical system were ≤ 2.1° for the ROM variables, <12°/s for maximum velocity, and ≤3.0°/s for mean velocity. In conclusion, VR is a useful assessment device for ROM and velocity measurements with clinically acceptable biases. It is a feasible tool for the objective measurement of cervical kinematics in the clinic.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)

Nyckelord

neck pain
cervical
virtual reality
VR
3D motion capture
validity
agreement
correlation
range of motion
velocity
Physiotherapy
Fysioterapi
Biomedical Engineering
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Forsberg, Karin
Jirlén, Johan
Jacobson, Inger
Röijezon, Ulrik
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Sjukgymnastik
Artiklar i publikationen
Sensors
Av lärosätet
Luleå tekniska universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy