SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ltu-31392"
 

Sökning: id:"swepub:oai:DiVA.org:ltu-31392" > Blind identificatio...

Blind identification strategies for room occupancy estimation

Ebadat, Afrooz (författare)
KTH,Reglerteknik,School of Electrical Engineering, KTH Royal Institute of Technology
Bottegal, Giulio, 1984- (författare)
KTH,Reglerteknik,School of Electrical Engineering, KTH Royal Institute of Technology
Varagnolo, Damiano (författare)
KTH,Luleå tekniska universitet,Signaler och system,Reglerteknik
visa fler...
Wahlberg, Bo (författare)
KTH,Reglerteknik,School of Electrical Engineering, KTH Royal Institute of Technology
Hjalmarsson, Håkan, 1962- (författare)
KTH,Reglerteknik,School of Electrical Engineering, KTH Royal Institute of Technology
Johansson, Karl Henrik (författare)
KTH,Reglerteknik,ACCESS Linnaeus Centre,School of Electrical Engineering, KTH Royal Institute of Technology
visa färre...
 (creator_code:org_t)
Piscataway, NJ : IEEE Communications Society, 2015
2015
Engelska.
Ingår i: 2015 European Control Conference (ECC). - Piscataway, NJ : IEEE Communications Society. - 9783952426937 ; , s. 1315-1320
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • We propose and test on real data a two-tier estimation strategy for inferring occupancy levels from measurements of CO2 concentration and temperature levels. The first tier is a blind identification step, based either on a frequentist Maximum Likelihood method, implemented using non-linear optimization, or on a Bayesian marginal likelihood method, implemented using a dedicated Expectation-Maximization algorithm. The second tier resolves the ambiguity of the unknown multiplicative factor, and returns the final estimate of the occupancy levels. The overall procedure addresses some practical issues of existing occupancy estimation strategies. More specifically, first it does not require the installation of special hardware, since it uses measurements that are typically available in many buildings. Second, it does not require apriori knowledge on the physical parameters of the building, since it performs system identification steps. Third, it does not require pilot data containing measured real occupancy patterns (i.e., physically counting people for some periods, a typically expensive and time consuming step), since the identification steps are blind.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)

Nyckelord

Reglerteknik
Control Engineering
Möjliggörande IKT (FOI)
Enabling ICT (AERI)
Intelligent industrial processes (AERI)
Intelligenta industriella processer (FOI)
System identification

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy