SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ltu-60720"
 

Sökning: id:"swepub:oai:DiVA.org:ltu-60720" > Integrated electrom...

Integrated electromagnetic data investigation of a Mesozoic CO2 storage target reservoir-cap-rock succession, Svalbard

Beka, Thomas I. (författare)
Faculty of Science and Technology, UiT-The Arctic University of Norway
Senger, Kim (författare)
Department of Arctic Geology, The University Centre in Svalbard
Autio, Uula A (författare)
Oulu Mining School, Geophysics, University of Oulu
visa fler...
Smirnov, Maxim (författare)
Luleå tekniska universitet,Geovetenskap och miljöteknik
Birkelund, Yngve (författare)
Faculty of Science and Technology, UiT-The Arctic University of Norway
visa färre...
 (creator_code:org_t)
Elsevier, 2017
2017
Engelska.
Ingår i: Journal of Applied Geophysics. - : Elsevier. - 0926-9851 .- 1879-1859. ; 136, s. 417-430
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Recently acquired time-domain electromagnetic (TEM) and magnetotelluric (MT) data sets are utilized in the first electromagnetic (EM) characterization of a geological CO2 storage target site in Adventdalen, Arctic Norway. Combining the two EM data sets enabled to resolve the electrical resistivity structure of the target site better than either of the methods alone. 2D inverting the MT data in the audio period interval (0.003–1 s) with supporting input derived from the TEM data (0.01–10 ms) provided a geologically meaningful resistivity model that included information not previously evident from existing seismic and borehole data. The ca. 1.8 × 1 km 2D resistivity model displays a laterally constrained highly conductive anomaly (ca. 10 Ω m) at about 400–500 m depth, where reflectors of a parallel seismic section are concealed and core samples indicate a highly fractured décollement zone formed during Paleogene compression. The base of the permafrost is imaged at ca. 200 m depth. Synthetic inversion tests, however, suggest that this may be exaggerated by tens of meters, due to a thin conductive layer present approximately between 10 and 25 m depth. The resistivity model does not give indication for a fluid pathway we can connect to leakage, in line with water injection and leak-off tests in the reservoir and cap-rock, both of which indicate a sealing shale-dominated cap-rock separating an over-pressured compartment above the sealing shale from a severely under-pressured reservoir interval. The results we present indicate the advantage of integrating EM exploration techniques in a CO2 reservoir-cap-rock study to obtain a more complete picture.

Ämnesord

NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Geofysik (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Geophysics (hsv//eng)

Nyckelord

Prospekteringsgeofysik
Exploration Geophysics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy