Experimental and Simulation Validation of ABHE for Disinfection of Legionella in Hot Water Systems

Altorkmany, Lobna (författare)
Luleå tekniska universitet,Arkitektur och vatten,Luleå tekniska universitet (LTU),Luleå University of Technology (LTU)
Kharseh, Mohamad, 1980 (författare)
Civil Environmental Engineering Department, Chalmers University of Technology,Chalmers tekniska högskola,Chalmers University of Technology
Ljung, Anna-Lena (författare)
Luleå tekniska universitet,Strömningslära och experimentell mekanik,Luleå tekniska universitet (LTU),Luleå University of Technology (LTU)
visa fler...
Lundström, Staffan (författare)
Luleå tekniska universitet,Strömningslära och experimentell mekanik,Luleå tekniska universitet (LTU),Luleå University of Technology (LTU)
visa färre...
 (creator_code:org_t)
Elsevier, 2017
2017
Engelska.
Ingår i: Applied Thermal Engineering. - : Elsevier. - 1359-4311 .- 1873-5606. ; 116, s. 253-265
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The work refers to an innovative system inspired by nature that mimics the thermoregulation system that exists in animals. This method, which is called Anti Bacteria Heat Exchanger (ABHE), is proposed to achieve continuous thermal disinfection of bacteria in hot water systems with high energy efficiency. In particular, this study aims to demonstrate the opportunity to gain energy by means of recovering heat over a plate heat exchanger. Firstly, the thermodynamics of the ABHE is clarified to define the ABHE specification. Secondly, a first prototype of an ABHE is built with a specific configuration based on simplicity regarding design and construction. Thirdly, an experimental test is carried out. Finally, a computer model is built to simulate the ABHE system and the experimental data is used to validate the model. The experimental results indicate that the performance of the ABHE system is strongly dependent on the flow rate, while the supplied temperature has less effect. Experimental and simulation data show a large potential for saving energy of this thermal disinfection method by recovering heat. To exemplify, when supplying water at a flow rate of 5 kg/min and at a temperature of 50 °C, the heat recovery is about 1.5 kW while the required pumping power is 1 W. This means that the pressure drop is very small compared to the energy recovered and consequently high saving in total cost is promising.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Vattenteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Water Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Heat transfer
Legionella
Plate heat exchanger
Modeling Water thermal treatment
Vattenteknik
Water Resources Engineering
Strömningslära
Fluid Mechanics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy