SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ltu-74362"
 

Sökning: id:"swepub:oai:DiVA.org:ltu-74362" > A practical non-enz...

A practical non-enzymatic urea sensor based on NiCo2O4 nanoneedles

Amin, Sidra (författare)
Luleå tekniska universitet,Materialvetenskap,National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistan.Department of Chemistry, Shaheed Benazir Bhutto University, Shaheed Benazirabad, Pakistan
Tahira, Aneela (författare)
Luleå tekniska universitet,Materialvetenskap
Solangi, Amber (författare)
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistan
visa fler...
Beni, Valerio (författare)
RISE Acreo, Research Institute of Sweden, Norrköping, Sweden
Morante, J.R (författare)
Catalonia Institute for Energy Research (IREC), Barcelona, Spain
Liu, Xianjie (författare)
Department of Physics, Chemistry and Biology, Surface Physics and Chemistry, Linköping University, Faculty of Science & Engineering, Sweden
Falhman, Mats (författare)
Department of Physics, Chemistry and Biology, Surface Physics and Chemistry, Linköping University, Faculty of Science & Engineering, Sweden
Mazzaro, Raffaello (författare)
Luleå tekniska universitet,Materialvetenskap
Ibupoto, Zafar (författare)
Luleå tekniska universitet,Materialvetenskap,Institute of Chemistry, University of Sindh, Jamshoro, Pakistan
Vomiero, Alberto (författare)
Luleå tekniska universitet,Materialvetenskap
visa färre...
 (creator_code:org_t)
Royal Society of Chemistry, 2019
2019
Engelska.
Ingår i: RSC Advances. - : Royal Society of Chemistry. - 2046-2069. ; 9:25, s. 14443-14451
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We propose a new facile electrochemical sensing platform for determination of urea, based on a glassy carbon electrode (GCE) modified with nickel cobalt oxide (NiCo2O4) nanoneedles. These nanoneedles are used for the first time for highly sensitive determination of urea with the lowest detection limit (1 μM) ever reported for the non-enzymatic approach. The nanoneedles were grown through a simple and low-temperature aqueous chemical method. We characterized the structural and morphological properties of the NiCo2O4 nanoneedles by TEM, SEM, XPS and XRD. The bimetallic nickel cobalt oxide exhibits nanoneedle morphology, which results from the self-assembly of nanoparticles. The NiCo2O4 nanoneedles are exclusively composed of Ni, Co, and O and exhibit a cubic crystalline phase. Cyclic voltammetry was used to study the enhanced electrochemical properties of a NiCo2O4 nanoneedle-modified GCE by overcoming the typical poor conductivity of bare NiO and Co3O4. The GCE-modified electrode is highly sensitive towards urea, with a linear response (R2 = 0.99) over the concentration range 0.01–5 mM and with a detection limit of 1.0 μM. The proposed non-enzymatic urea sensor is highly selective even in the presence of common interferents such as glucose, uric acid, and ascorbic acid. This new urea sensor has good viability for urea analysis in urine samples and can represent a significant advancement in the field, owing to the simple and cost-effective fabrication of electrodes, which can be used as a promising analytical tool for urea estimation.

Ämnesord

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Nyckelord

Experimentell fysik
Experimental Physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy