SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ltu-86263"
 

Sökning: id:"swepub:oai:DiVA.org:ltu-86263" > Removal of rubber, ...

Removal of rubber, bitumen and other microplastic particles from stormwater by a gross pollutant trap - bioretention treatment train

Lange, Katharina (författare)
Luleå tekniska universitet,Arkitektur och vatten
Magnusson, Kerstin (författare)
IVL Swedish Environmental Research Institute, Kristineberg Marine Research Station, Fiskebäckskil, Sweden
Viklander, Maria (författare)
Luleå tekniska universitet,Arkitektur och vatten
visa fler...
Blecken, Godecke-Tobias (författare)
Luleå tekniska universitet,Arkitektur och vatten
visa färre...
 (creator_code:org_t)
Elsevier, 2021
2021
Engelska.
Ingår i: Water Research. - : Elsevier. - 0043-1354 .- 1879-2448. ; 202
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Microplastic particles in stormwater pose significant threats to the environment. This study investigated how effective a stormwater treatment train was at removing rubber, bitumen and other microplastics (incl. fibers, fragments, and paint particles) in the 100-300 µm and >300 µm size fractions from highway runoff. The two treatment trains comprise a gross pollutant trap (GPT) followed by either a vegetated bioretention cell or non-vegetated sand filter. Flow-proportional composite samples were taken from the highway runoff, GPT outflow and the outflow from the two parallel filters during nine rain events to determine overall treatment performance, as well as the performance of individual system components. The identified rubber, bitumen and other microplastic particles mainly represented the 100-300 µm fraction and included high ratios of rubber (30%) and bitumen (60%). Overall, the treatment train efficiently removed rubber, bitumen and other microplastic particles in the 100-300 µm size fraction from the stormwater. The filter cells accounted for a major share of this removal, as the GPT did not reduce microplastic particle concentrations. This observation is likely explained by the fact that the rubber, bitumen and other microplastic particles have a density close to the density of water and thus removal by sedimentation is decreased. This identified an inherent weakness of the system; more specifically, the high microplastic concentrations in the surface water of the GPT means there can be a risk of microplastic release through overflow pits when inflows surpass the system capacity. Despite some differences, both the vegetated bioretention cell and the non-vegetated sand filter removed rubber, bitumen and other microplastic particles to similar extent.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Vattenteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Water Engineering (hsv//eng)

Nyckelord

Stormwater biofilter
pre-sedimentation
microplastic
tyre wear
bitumen
microlitter
VA-teknik
Urban Water Engineering
Centrumbildning - Centrum för dagvattenhantering (DRIZZLE)
Centre - Centre for Stormwater Management (DRIZZLE)
Vatten

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy