SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:ltu-90245"
 

Search: id:"swepub:oai:DiVA.org:ltu-90245" > Minimizing the Fluo...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Minimizing the Fluoride Load in Water Using the Electrocoagulation Method: An Experimental Approach

Al-Samarrai, Shatha Y. (author)
Chemistry Department, College of Science, Tikrit University, Tikrit 34001, Iraq
Karaghool, Haneen A. Kh (author)
Environmental Engineering Department, College of Engineering, Tikrit University, Tikrit 34001, Iraq
Abdulridha, Ali (author)
Civil Engineering Department, College of Engineering, University of Warith Al-Anbiyaa, Karbala 56001, Iraq
show more...
Al-Ansari, Nadhir, 1947- (author)
Luleå tekniska universitet,Geoteknologi
Salman, Jasim M. (author)
Department of Biology, College of Science, University of Babylon, Hillah 51001, Iraq
Al-Sareji, Osamah J. (author)
Sustainability Solutions Research Lab, Faculty of Engineering, University of Pannonia, Egyetem Str. 10, 8200 Veszprém, Hungary
show less...
 (creator_code:org_t)
2022-03-17
2022
English.
In: Environments. - : MDPI. - 2076-3298. ; 9:3
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The abundant presence of fluoride (F-) in surface water bodies is an environmental concern because of its effects on human health; medical reports confirmed that fluoride intake above 1.5 mg/L leads to many health complications, including but not limited to weak bones and enamel fluorosis. Thus, the World Health Organisation (WHO) defines 1.20 mg/L as the maximum permissible F concentration in drinking water. The electrocoagulation method (EC) is globally practised to remove many pollutants from water due to its cost-effectiveness, safety, and ease of use. However, EC has some drawbacks, such as the lack of reactors’ design. In this study, a new EC reactor, which uses four drilled aluminium electrodes and a variant cross-section section container, was designed and used to remove F- from water. The design of the new EC eliminated the need for water mixers. The ability of the new EC unit to remove F- from synthetic water was evaluated at different current densities (CD) (1-3 mA/cm2), electrode distances (ELD) (5-15 mm), pH of the solution (pHoS) (4-10), and initial F- concentrations (IFC) (5-20 mg/L). The outcomes of this study prove that the new reactor could remove as much as 98.3% of 20 mg/l of F- at CD, ELD, pHoS, and IFC of 2 mA/cm2, 5 mm, and 4 and 10 mg/L, respectively.

Subject headings

NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Geokemi (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Geochemistry (hsv//eng)
NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Environmental Sciences (hsv//eng)

Keyword

electrocoagulation
fluoride removal
iron electrodes
optimization
RSM
Soil Mechanics
Geoteknik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view