SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ltu-9216"
 

Sökning: id:"swepub:oai:DiVA.org:ltu-9216" > Experimental invest...

Experimental investigations of transient pressure variations in a high head model Francis turbine during start-up and shutdown

Trivedi, Chirag (författare)
Luleå tekniska universitet,Strömningslära och experimentell mekanik
Cervantes, Michel (författare)
Luleå tekniska universitet,Strömningslära och experimentell mekanik
Gandhi, B.K. (författare)
Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee
visa fler...
Dahlhaug, Ole G. (författare)
Department of Energy and Process Engineering, Water Power Laboratory, Norwegian University of Science and Technology, Trondheim
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: Journal of Hydrodynamics. - 1001-6058 .- 1000-4874. ; 26:2, s. 277-290
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Penetration of the power generated using wind and solar energy to electrical grid network causing several incidents of the grid tripping, power outage, and frequency drooping. This has increased restart (star-stop) cycles of the hydroelectric turbines significantly since grid connected hydroelectric turbines are widely used to manage critical conditions of the grid. Each cycle induces significant stresses due to unsteady pressure loading on the runner blades. The presented work investigates the pressure loading to a high head (Hp = 377 m, Dp = 1.78 m) Francis turbine during start-stop. The measurements were carried out on a scaled model turbine (HM = 12.5 m, DM = 0.349 m). Total four operating points were considered. At each operating point, three schemes of guide vanes opening and three schemes of guide vanes closing were investigated. The results show that total head variation is up to 9% during start-stop of the turbine. On the runner blade, the maximum pressure amplitudes are about 14 kPa and 16 kPa from the instantaneous mean value of 121 kPa during rapid start-up and shutdown, respectively, which are about 1.5 times larger than that of the slow start-up and shutdown. Moreover, the maximum pressure fluctuations are given at the blade trailing edge.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Nyckelord

Strömningslära
Fluid Mechanics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy