SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:mau-16234"
 

Sökning: id:"swepub:oai:DiVA.org:mau-16234" > Biomechanical, Biol...

Biomechanical, Biologic, and Clinical Outcomes of Undersized Implant Surgical Preparation : A Systematic Review

Stocchero, Michele (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Toia, Marco (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Cecchinato, Denis (författare)
Institute Franci, Private Practice, Padova, Italy
visa fler...
Becktor, Jonas P (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Coelho, Paulo G (författare)
Department of Biomaterials and Biomimetics, New York University, New York, NY, United States
Jimbo, Ryo (författare)
Malmö högskola,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
Quintessence, 2016
2016
Engelska.
Ingår i: International Journal of Oral & Maxillofacial Implants. - : Quintessence. - 0882-2786 .- 1942-4434. ; 31:6, s. 1247-1263
  • Forskningsöversikt (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To compile the current evidence on biomechanical, biologic, and clinical outcomes of undersized surgical preparation protocols in dental implant surgery. MATERIALS AND METHODS: An electronic search using three different databases (PubMed, Web of Science, and Cochrane Library) and a manual hand search were performed including in vitro, animal, and clinical studies published prior to October 2015. Studies in which an undersized drilling protocol was compared with a nonundersized drilling protocol were included. RESULTS: From an initial selection of 1,655 titles, 29 studies met the inclusion criteria, including 14 biomechanical, 7 biologic, 6 biologic and biomechanical, and 2 clinical. Due to methodologic variation, meta-analysis was not performed. Several studies showed that implants inserted with an undersized drilling approach reached a significantly higher insertion torque value than conventional drilling in low-density substrates, while this effect is less evident if a thick cortical layer is present. Similar results in terms of boneto-implant contact (BIC) were achieved in the longer term between implants inserted with undersized and nonundersized protocols. Results in the short term were inconclusive. Clinical studies did not show negative outcomes for undersized drilling, although clinical evidence was sparse. No data are available on marginal bone loss. CONCLUSION: From the biomechanical standpoint, an undersized drilling protocol is effective in increasing insertion torque in low-density bone. Biologic response in long-term healing after undersized implant placement is comparable to that in the nonundersized surgical drilling protocol. Clinical studies indicate that performing an undersized drilling protocol on low-density bone is a safe procedure; however, more extensive studies are needed to confirm these data.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

dental implant
primary stability
secondary stability
surgical protocol
systematic review
undersized osteotomy
Medicine
Animals
Dental Implantation
Endosseous
Dental Implants
Dental Models
Dental Prosthesis Design
Humans
Surface Properties
Torque

Publikations- och innehållstyp

ref (ämneskategori)
for (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy