Filter Plate–Based Screening of MIP SPE Materials for Capture of the Biomarker Pro-Gastrin-Releasing Peptide

Jagadeesan, Kishore (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Rossetti, Cecilia (författare)
Department of Pharmaceutical Chemistry, School of Pharmacy, University of Oslo, Oslo, Norway
Qader, Abed Abdel (författare)
Department of Environmental Chemistry and Analytical Chemistry, Institute for Environmental Research (INFU), Technical University of Dortmund, Dortmund, Germany
visa fler...
Reubsaet, Leon (författare)
Department of Pharmaceutical Chemistry, School of Pharmacy, University of Oslo, Oslo, Norway
Sellergren, Börje (författare)
Malmö University,Malmö högskola,Institutionen för biomedicinsk vetenskap (BMV),Biofilms Research Center for Biointerfaces
Laurell, Thomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Ekström, Simon (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Sage Publications, 2017
2017
Engelska.
Ingår i: SLAS Discovery. - : Sage Publications. - 2472-5560 .- 2472-5552. ; 22:10, s. 1253-1261
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Affinity-based solid-phase extraction (SPE) is an attractive low-cost sample preparation strategy for biomarker analysis. Molecularly imprinted polymers (MIPs) as affinity sorbents offer unique opportunities for affinity SPE, due to their low manufacturing cost and high robustness. A limitation is the prediction of their affinity; therefore, screening of analyte recovery and specificity within a large range of SPE conditions is important in order to ensure high-sensitivity detection and assay reproducibility. Here, a µ-SPE method for screening of the MIP-SPE materials using a commercial 384-well filter plate is presented. The method allows for rapid and automated screening using 10?30 µL of packed SPE sorbent per well and sample volumes in the range of 10?70 µL. This enables screening of many different SPE sorbents while simultaneously identifying optimal SPE conditions. In addition, the 384-well format also facilitates detection with a multitude of analytical platforms. Performance of the µ-MIP-SP

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

sample preparation
mass spectrometry
separations or chromatography
protein chemistry
protein labeling
proteomics
biomarkers
Sample preparation
mass spectromery
SEPARATIONS
chromatography
protein chemistry
Biomarkers
protein labeling

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy