SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:mau-6894"
 

Sökning: id:"swepub:oai:DiVA.org:mau-6894" > Comparison of inter...

Comparison of interim restorations fabricated by CAD/CAM with those fabricated manually

Rayyan, Mohammad M. (författare)
Aboushelib, Moustafa (författare)
Sayed, Nagwa M. (författare)
visa fler...
Ibrahim, Ahmed (författare)
Jimbo, Ryo (författare)
Malmö högskola,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
Mosby, 2015
2015
Engelska.
Ingår i: The Journal of prosthetic dentistry (Print). - : Mosby. - 0022-3913 .- 1097-6841. ; 114:3, s. 414-419
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Statement of problem. Interim restorations represent an essential treatment step; however, the optimal resin material for long-term interim restorations requires investigation. Purpose. The purpose of this in vitro study was to compare the color stability, water sorption, wear resistance, surface hardness, fracture resistance, and microleakage of computer-aided design/computer-aided manufacturing-(CAD/CAM) fabricated interim restorations with those of manually fabricated interim restorations. Material and methods. Epoxy replicas were made from a prepared maxillary first premolar. On the replicas, interim crowns were fabricated and divided into the following groups: CAD/CAM poly(methyl methacrylate) (PMMA) blocks (CC), autopolymerizing temporary resin (AP), automix temporary resin (AM), and thermoplastic resin (TP). After cementation, all specimens were subjected to thermocycling and dynamic fatigue. The CIE Laboratory color coordinates were then recorded before and after immersion in coffee, tea, carbonated cola, and red wine. Water sorption was evaluated by using an immersion technique. Wear resistance was measured in a surface abrasion device. Vickers microhardness was measured on polished specimens. Fracture resistance was evaluated by axial loading with a universal testing machine. Marginal dye penetration was evaluated by sectioning the interim restorations after immersion in methylene blue (alpha=.05). Results. Colorimetric analysis revealed a large degree of color alteration (SE) in the manually fabricated interim restorations: AP = Delta E of 6.7 +/- 2); AM = Delta E of 7.1 +/- 1.5), and TP = Delta E of =5.4 +/- 3.1. The CC group demonstrated color stability (Delta E=2.1 +/- 0.2). CAD/CAM interim restorations demonstrated significantly lower water sorption, higher wear resistance, higher surface hardness, and significantly higher fracture resistance (1 289 +/- 56N) compared with manually fabricated interim restorations (AP=996 +/- 45, AM=899 +/- 37, and TP=1179 +/- 41). The stereomicroscopic examination of sectioned specimens demonstrated the absence of dye penetration in all tested specimens. Conclusions. CAD/CAM interim crowns presented stable physical and mechanical properties and may be used for long-term interim restorations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Oral surgery & medicine
Dentistry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Rayyan, Mohammad ...
Aboushelib, Mous ...
Sayed, Nagwa M.
Ibrahim, Ahmed
Jimbo, Ryo
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
The Journal of p ...
Av lärosätet
Malmö universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy