Robust heartbeat detector based on weighted correlation and multichannel input : Implementation on the ECG recorded with textile electrodes

Rattfält, Linda, 1979- (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
Lindén, Maria (författare)
Mälardalens högskola,Akademin för innovation, design och teknik,Mälardalen University,Intelligent sensor systems department
Hult, Peter (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
visa fler...
Ask, Per (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
Borga, Magnus (författare)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
IGI Global, 2013
2013
Engelska.
Ingår i: International Journal of E-Health and Medical Communications. - : IGI Global. - 1947-315X .- 1947-3168. ; 4:1, s. 61-71
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to develop and evaluate a robust heartbeat detector for noisy electrocardiograms (ECGs) recorded with textile electrodes. The authors suggest a method based on weighted correlation in a multi-channel ECG to obtain a heartbeat detector. Signals were acquired during rest and at movements which simulate every day activities. From each recording a segment corresponding to a heartbeat was extracted and correlated with the whole signal. From the correlation data, heartbeat candidates were derived and weighted based on their variance similarity with the heartbeat model and previous heartbeats. Finally, the outputs of each channel were added to create the global output. The output was compared to the Pan Tompkins heartbeat detector. Results are promising for recordings at rest (sensitivity = 0.97, positive predictive value (PPV) = 0.97). For static muscle tension in the torso the results were much higher than the reference method (sensitivity = 0.77, PPV = 0.85). Corresponding values for the reference method were sensitivity = 0.96 and PPV = 0.95 at rest and sensitivity = 0.52 and PPV = 0.75 during muscle tension.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

Electrocardiogram monitoring (ECG monitoring)
Heartbeat detection
Multi-channel electrocardiogram (multi-channel ECG)
Noise suppression
Textile electrodes

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy