SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:mdh-53654"
 

Sökning: id:"swepub:oai:DiVA.org:mdh-53654" > Enabling smart cont...

Enabling smart control by optimally managing the State of Charge of district heating networks

Saletti, Costanza (författare)
Univ Parma, Dept Engn & Architecture, Parco Area Sci 181-A, I-43124 Parma, Italy.
Zimmerman, Nathan, 1983- (författare)
Mälardalens högskola,Framtidens energi
Morini, Mirko (författare)
Univ Parma, Dept Engn & Architecture, Parco Area Sci 181-A, I-43124 Parma, Italy.;Univ Parma, Ctr Energy & Environm CIDEA, Parco Area Sci 42, I-43124 Parma, Italy.
visa fler...
Kyprianidis, Konstantinos (författare)
Mälardalens högskola,Framtidens energi
Gambarotta, Agostino (författare)
Univ Parma, Dept Engn & Architecture, Parco Area Sci 181-A, I-43124 Parma, Italy.;Univ Parma, Ctr Energy & Environm CIDEA, Parco Area Sci 42, I-43124 Parma, Italy.
visa färre...
Univ Parma, Dept Engn & Architecture, Parco Area Sci 181-A, I-43124 Parma, Italy Framtidens energi (creator_code:org_t)
ELSEVIER SCI LTD, 2021
2021
Engelska.
Ingår i: Applied Energy. - : ELSEVIER SCI LTD. - 0306-2619 .- 1872-9118. ; 283
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Digitalization and smart control of district heating networks are emerging as key features to make these systems flexible and optimal. However, since effective and scalable methods for large-scale systems are currently unavailable, the implementation of smart controllers can be challenging and time-consuming. This is addressed herein by proposing a novel approach to include the thermal capacity of the connected buildings in the optimal control of large-scale heating networks. A reduced-order model of the aggregated communities supplied by a large-scale network is used to define their State of Charge, which is exploited to store or retrieve energy when convenient, while maintaining indoor comfort. This concept is included in a Model Predictive Controller that optimizes power plant management and heat distribution. The results show that the controller successfully shaves heat supply peaks to different regions up to 16% and reduces the difference between distribution and soil temperature up to 20%. At the same time, the return temperature is kept close to the set-point of 35 degrees C, which is lower than the historical operation and further reduces distribution heat losses. The procedure can be easily replicated to optimize systems of different sizes and to support their transition to efficient, smart district heating networks.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)

Nyckelord

District heating network
State of Charge
Building heat capacity
Model predictive control
Optimal management
Scalability

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy