SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:mdh-60388"
 

Sökning: id:"swepub:oai:DiVA.org:mdh-60388" > The Effect of Physi...

The Effect of Physical Faults on a Three-Shaft Gas Turbine Performance at Full- and Part-Load Operation

Salilew, Waleligne Molla (författare)
Univ Teknol Petronas, Mech Engn Dept, Bandar Seri Iskandar 32610, Perak, Malaysia.
Karim, Zainal Ambri Abdul (författare)
Univ Teknol Petronas, Ctr Automot Res & Elect Mobil CAREM, Bandar Seri Iskandar 32610, Perak, Malaysia.
Lemma, Tamiru Alemu (författare)
Univ Teknol Petronas, Mech Engn Dept, Bandar Seri Iskandar 32610, Perak, Malaysia.
visa fler...
Fentaye, Amare Desalegn (författare)
Mälardalens universitet,Framtidens energi
Kyprianidis, Konstantinos (författare)
Mälardalens universitet,Framtidens energi
visa färre...
Univ Teknol Petronas, Mech Engn Dept, Bandar Seri Iskandar 32610, Perak, Malaysia Univ Teknol Petronas, Ctr Automot Res & Elect Mobil CAREM, Bandar Seri Iskandar 32610, Perak, Malaysia. (creator_code:org_t)
2022-09-21
2022
Engelska.
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 22:19
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A gas path analysis approach of dynamic modelling was used to examine the gas turbine performance. This study presents an investigation of the effect of physical faults on the performance of a three-shaft gas turbine at full-load and part-load operation. A nonlinear steady state performance model was developed and validated. The datasheet from the engine manufacturer was used to gather the input and validation data. Some engineering judgement and optimization were used. Following validation of the engine performance model with the engine manufacturer data using physical fault and component health parameter relationships, physical faults were implanted into the performance model to evaluate the performance characteristics of the gas turbine at degradation state at full- and part-load operation. The impact of erosion and fouling on the gas turbine output parameters, component measurement parameters, and the impact of degraded components on another primary component of the engine have been investigated. The simulation results show that the deviation in the output parameters and component isentropic efficiency due to compressor fouling and erosion is linear with the load variation, but it is almost nonlinear for the downstream components. The results are discussed following the plots.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

gas turbine
performance model
steady-state
full-load
part-load performance
physical faults

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy